676 Chapter 17 Design of Two-Way Slabs<br />

b. Voided volume ( of 14-in. ) rib = 6.54 ft 3 on 3 × 3 −ft 2 area. Total weight of 9-ft 2 area is<br />

1.2(150) 9 × 17 − 6.54 = 1118 lb. Weight per square foot is 1118 = 125 psf.<br />

12 9<br />

c. Factored additional dead plus live load is 1.2(50) + 1.6(100) = 220 psf. Uniform q u at solid<br />

(head) = 255 + 220 ≈ 500 psf. Uniform q u (at ribbed area) = 125 + 220 = 345 psf.<br />

d. Loads on one panel (refer to Fig. 17.34): At the solid head, q u = 0.5(12) + 0.345(21) = 13.22<br />

K/ft. At the ribbed area, q u = 0.345(33) = 11.39 K/ft.<br />

3. Calculate shear and total static moment:<br />

V u (at face of column) =13.22(5.17)+ (11.39)(21) = 188 K<br />

2<br />

M 0 (at midspan) =188(15.67)−13.22(5.17)(13.09)− 11.39(10.5)2 = 1424 K ⋅ ft<br />

2<br />

4. Check punching shear (refer to Fig. 17.35):<br />

a. In the solid head at d/2 from the column face, h = 17 in., d = 17 − 1.25 = 15.75 in.,<br />

c (column) = 20 in., b 0 = 4(20 + 15.75) = 143 in., V u = 11.39(21 ft) + 13.22(12 ft) − 0.5(37.75/<br />

12) 2 = 393.4 K and<br />

(<br />

φV c = φ 2 + 4 ) √f<br />

′<br />

β c b 0 d<br />

β = 1.0<br />

(<br />

φV c = 0.75 2 + 4 ) √ 5000<br />

× 143 × 15.75<br />

1.0 1000<br />

= 716 K<br />

( )<br />

αs d √f<br />

′<br />

φV c = φ + 2<br />

b c b 0 d<br />

0<br />

( ) √ 40 × 15.75 5000<br />

= 0.75<br />

+ 2 × 143 × 15.75<br />

143 1000<br />

= 765 K<br />

φV c = φ4λ √ (√ )<br />

5000<br />

f c ′ b 0 d = 0.75(4)(1.0)<br />

(143)(15.75) =478 K (controls) > V<br />

1000<br />

u<br />

Waffle slab (looking upward).