966 Chapter 23 Review Problems on <strong>Concrete</strong> Building Components<br />

5. Column design calculations—north/south direction:<br />

M (K.ft) 2.98<br />

P u (K) 27.45<br />

h (in.) 12<br />

(<br />

(2.98 K ⋅ ft)<br />

12 in<br />

ft<br />

M n =<br />

= 55.01 K ⋅ in.<br />

0.65<br />

55.01<br />

R n =<br />

4(144)(12) = 0.007<br />

K n =<br />

)<br />

P n<br />

f ′ c A g<br />

= 42.23<br />

4(144) = 0.07<br />

From Figure 11.16 charts (c) and (d), ρ g = 0.01<br />

A s = ρ g A g = 0.01(144 in. 2 ) = 1.44 in. 2<br />

0.01A g ≤ A s ≤ 0.08A g<br />

→ 4 # 6 bars; d b = 0.75 in.<br />

6. Design for ties: (ACI Code, Section 25.7.2)<br />

No. 3 ties for longitudinal reinforcement bars size no. 10 or smaller → d tie = 0.375 in.<br />

Vertical spacing of ties shall be the smallest of:<br />

16d bar = 16(0.75 in.) = 12 in. (governs)<br />

48d tie = 48(0.375in.) = 18 in.<br />

Least dimension of compression member = 12 in.<br />

7. Check for splice length in compression:<br />

l sc = 0.0005f y d b = 0.0005(60000)(0.75) =22.5in. ≥ 12 in. (ACI 25.5.5.1)<br />

8. Check for splice length in tension (ACI Code, Section 25.4.2.4)<br />

Since A s provided<br />

A s required < 2, use Class B splice: 1.3l d (ACI Code, Section 25.5.2.1)<br />

( )<br />

fy ψ t ψ e<br />

1.3l d = 1.3<br />

20λ √ 60000(1)(1)<br />

d b =(1.3)<br />

f c<br />

′ (20)(1)( √ (0.75) = 46.25 in. ≥ 12 in.<br />

4000<br />

9. Details of column cross section is shown in Figure 23.15<br />

2″<br />

8″ 4 no. 6<br />

12″<br />

2″<br />

12″<br />

Figure 23.15 Cross section details of column C.