Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
V<br />
I<br />
LS<br />
LS<br />
= V<br />
FS<br />
== I<br />
FS<br />
VFP<br />
VLP<br />
3 6600<br />
3 = 3 = = = 550 V ;<br />
a 3 a 12<br />
= aI = aI = 12 × 10 = 120 A.<br />
FP<br />
c). Untuk hubungan ∆-Y :<br />
VFP<br />
VLP<br />
6600<br />
VLS<br />
= VFS<br />
3 = 3 = 3 = 3 = 953 V ;<br />
a a 12<br />
I LP 10<br />
I LS = I FS = aI FP = a = 12 = 69,3 A.<br />
3 3<br />
d) Untuk hubungan Y-∆ :<br />
V<br />
I<br />
LS<br />
LS<br />
= V<br />
= I<br />
FS<br />
FS<br />
V<br />
=<br />
a<br />
FP<br />
3 = aI<br />
LP<br />
1 VLP<br />
= =<br />
a 3<br />
FP<br />
3 = aI<br />
1<br />
12<br />
LP<br />
6600<br />
= 318 V ;<br />
3<br />
3 = 12 × 10 ×<br />
3 = 208 A .<br />
Dengan mengabaikan rugi-rugi daya keluaran sama dengan daya<br />
masukan.<br />
S keluaran<br />
= Smasukan<br />
= VLP<br />
I LP<br />
3 = 6,6 × 10 3 = 114,3 kVA.<br />
Soal-Soal<br />
1. Sebuah transformator satu fasa diinginkan untuk menurunkan<br />
tegangan bolak-balik 50 Hz dari 20 kV ke 250 V dalam keadaan tak<br />
berbeban. Jika fluksi magnetik dalam inti transformator adalah sekitar<br />
0.08 Wb, tentukan jumlah lilitan belitan primer dan sekundernya.<br />
2. Sebuah transformator tipe inti hendak digunakan untuk menurunkan<br />
tegangan bolak-balik 50 Hz, dari 3000 ke 220 V. Inti berpenampang<br />
persegi dengan ukuran 20 cm × 20 cm. Hitunglah jumlah lilitan pada<br />
kedua belitan jika kerapatan fluksi pada inti dibatasi 1 Wb/m 2 .<br />
3. Jumlah lilitan belitan primer dan sekunder transformator satu fasa<br />
adalah 200 dan 100 lilitan dan resistansinya 0,255 Ω dan 0,074 Ω.<br />
Hitunglah resistansi belitan primer dilihat di sekunder, resistansi<br />
sekunder dilihat di primer, dan resistansi total di sisi primer.<br />
48 Sudaryatno Sudirham, <strong>Analisis</strong> <strong>Rangkaian</strong> Listrik (3)