Overview of DIL Switch Functions<br />

Single or double-leaf operation<br />

Single-leaf operation<br />

Double-leaf operation<br />

With/without leaf offset (only with double-leaf operation)<br />

Without leaf offset: leaf A and B open and close simultaneously<br />

With leaf offset: leaf A opens <strong>be</strong>fore leaf B and leaf B closes <strong>be</strong>fore leaf A<br />

Leaf selection/size of leaf offset<br />

Teach in leaf B/small leaf offset<br />

Teach in leaf A/large leaf offset<br />

Normal operation/Set-up mode<br />

Set-up mode<br />

Normal mode in press-and-release operation<br />

DIL 5 DIL 6 Safety device SE1 in OPEN direction (connection at terminal 73)<br />

ON ON 2-wire photocell<br />

ON OFF Monitored photocell<br />

OFF OFF • No safety device: wire jumper <strong>be</strong>tween terminals 20/73, = delivery condition<br />

• Unmonitored photocell<br />

DIL 7 DIL 8 Safety device SE2 in CLOSE direction (connection at terminal 72)<br />

ON ON 2-wire photocell<br />

ON OFF Monitored photocell<br />

OFF OFF • No safety device: wire jumper <strong>be</strong>tween terminals 20/72, = delivery condition<br />

• Unmonitored photocell<br />

DIL 9<br />

ON<br />

OFF<br />

Safety device SE2 in CLOSE direction (connection at terminal 72) as a through-traffic photocell<br />

Safety photocell activated as a through-traffic photocell<br />

Safety photocell not activated as a through-traffic photocell<br />

DIL 10 DIL 11 Operator function Option relay function<br />

ON ON Automatic timed closing, pre-warning time<br />

for each leaf movement<br />

Relay clocks rapidly during the pre-warning time,<br />

normally during the travel phase and is OFF during<br />

the hold-open phase<br />

OFF ON Automatic timed closing, pre-warning time<br />

only for automatic timed closing<br />

Relay clocks rapidly during the pre-warning time,<br />

normally during the travel phase and is OFF during<br />

the hold-open phase<br />

Relay clocks rapidly during the pre-warning time,<br />

normally during the travel phase<br />

ON OFF No automatic timed closing, pre-warning<br />

time for each leaf movement<br />

OFF OFF No special function Relay picks up in the CLOSE end-of-travel position<br />

DIL 12<br />

ON<br />

OFF<br />

DIL 13<br />

ON<br />

OFF<br />

DIL 14<br />

ON<br />

OFF<br />

DIL 15<br />

ON<br />

OFF<br />

DIL 16<br />

ON<br />

OFF<br />

Hold-open phase setting<br />

Set hold-open phase<br />

Without function<br />

Impulse during the hold-open phase<br />

• Impulse cancels the hold-open phase<br />

• Impulse during gate travel stops the gate<br />

Impulse extends the hold-open phase<br />

Reversal limit<br />

Set reversal limit<br />

Without function<br />

Starting point for slow speed<br />

Set the desired starting points<br />

Without function<br />

Slow travel speed for all runs/delete slow speed starting points<br />

Slow travel speed for all runs/delete slow speed starting points<br />

Without function<br />

48 TR10A078 RE / 07.2010