OUT<br />

IN<br />

Alarms<br />

Data Acquisition Circuitry<br />

External<br />

Trigger<br />

Control<br />

Introduction to the <strong>34980A</strong> 1<br />

As shown below, the <strong>34980A</strong>'s main system processor controls all of the<br />

basic functionality of the instrument. This is where the instrument<br />

communicates with the plug- in modules, interacts with command<br />

transactions over the remote interfaces, and controls the optional<br />

internal DMM. The main system processor also performs Mx+B scaling<br />

operations, monitors alarm conditions, converts transducer measurements<br />

to engineering units, adds time stamp information to scanned<br />

measurements, and stores measurement data in memory.<br />

LAN<br />

USB<br />

GPIB<br />

AC<br />

Power<br />

Optional<br />

Internal<br />

DMM<br />

Main<br />

System<br />

Processor<br />

I<br />

Hi <strong>Measure</strong><br />

Lo <strong>Measure</strong><br />

Hi Sense<br />

Lo Sense<br />

Analog<br />

Bus<br />

Digital Bus<br />

ABUS1<br />

ABUS2<br />

ABUS3<br />

ABUS4<br />

The main system processor also controls activity on the four hardware<br />

alarm outputs and external triggering lines. You can use the alarm output<br />

lines to trigger external alarm lights, sirens, or send a TTL pulse to your<br />

control system.<br />

The <strong>34980A</strong> provides four 2- wire internal Analog Buses for easier signal<br />

routing. You can route your measurements directly to the optional<br />

internal DMM using the <strong>34980A</strong> multiplexer and matrix modules or you<br />

can connect to external signals via the Analog Bus connector located on<br />

the instrument's rear panel. Since four 2- wire buses are provided, you<br />

can dedicate one bus for use with the internal DMM while using the<br />

other three buses for module extensions or additional signal routing<br />

between modules.<br />

<strong>Agilent</strong> <strong>34980A</strong> Mainframe User’s Guide 5<br />

Slot<br />

1000<br />

Slot<br />

2000<br />

Slot<br />

3000<br />

Slot<br />

8000