General <strong>Measure</strong>ment Configuration<br />

Features and Functions 3<br />

This section contains general information to help you configure the<br />

instrument for making measurements. Since these parameters are used<br />

by several measurement functions, the discussion is combined into one<br />

common section. Refer to the later sections in this chapter for more<br />

information on parameters specific to each measurement function.<br />

Overview of <strong>Measure</strong>ment Modes<br />

Two modes of operation are available with the <strong>34980A</strong>, depending on the<br />

level of switching and measurement that you wish to directly control: <br />

the Stand- Alone DMM Mode and the Scanning Mode.<br />

Stand-Alone DMM Mode<br />

In the Stand- Alone DMM Mode, the internal DMM makes measurements of<br />

whatever signals are present on the Analog Buses. In this mode, you have<br />

full control of what channel relays are closed and connected to the<br />

appropriate Analog Bus for the measurement. You can route your signals<br />

directly to the internal DMM using the <strong>34980A</strong> multiplexer and matrix<br />

modules, or you can connect to external signals via the Analog Bus<br />

connector located on instrument’s rear panel (see “Analog Buses” on<br />

page 84).<br />

Front Panel Operation:<br />

To configure the most common measurement parameters for the<br />

internal DMM, use the DMM (Configure) key.<br />

To close the desired channel relays and Analog Bus relays, use the<br />

Close key. The Analog Bus relays on the multiplexer and matrix modules<br />

are numbered s911, s912, s913, etc.<br />

To auto- trigger the internal DMM and display continuous readings,<br />

press the DMM (<strong>Measure</strong>) key. Press the DMM (<strong>Measure</strong>) key again to<br />

stop taking measurements.<br />

For additional triggering control and to store DMM readings in memory,<br />

use the Scan (Configure) key to set the triggering parameters, and then<br />

press and hold the Scan (<strong>Measure</strong>) key to initiate the DMM<br />

measurement. These selections are available only for stand- alone DMM<br />

use when a scan list has not been defined (see “Stand- Alone DMM<br />

Mode” on page 81).<br />

To stop storing readings in memory during long measurements, <br />

press and hold the Scan (<strong>Measure</strong>) key.<br />

<strong>Agilent</strong> <strong>34980A</strong> Mainframe User’s Guide 81