1 Introduction to the <strong>34980A</strong><br />

The Actuator / General-Purpose <strong>Switch</strong>es<br />

You can think of the 34937A, 34938A, and 34939A modules as a control<br />

outputs because they are often used to control external power devices.<br />

For example, the 34937A provides 28 independent, isolated Form C<br />

(SPDT) switches. Each channel can switch up to 300V dc or ac rms. Each<br />

switch can also switch up to 1A dc or ac rms up to 60W maximum. For<br />

example, the maximum current that you can switch at 120V is 0.45A as<br />

shown below.<br />

120<br />

300<br />

100<br />

50<br />

30<br />

.2 .5 1<br />

For control applications, the GP modules have the following advantages:<br />

Higher voltage and power rating than the digital output channels.<br />

The actuator switches can also be used to control power devices.<br />

When used with high-power devices, however, it is critical that you<br />

provide protection to the switch from capacitive and inductive loads to<br />

ensure maximum relay life.<br />