- High Voltage Testing Techniques covering High voltage testing Radio references<br />

and Corona Studies in EHV lines, pollution performance on equipment, switching<br />

surge studies in power systems;<br />

- Testing <strong>of</strong> PVC cables and bushings, development and testing <strong>of</strong> capacitors, partial<br />

discharge phenomena in power apparatus;<br />

- Development <strong>of</strong> Polymeric insulating materials, paper insulating materials etc.<br />

and testing;<br />

- Design and development <strong>of</strong> optimal transmission line towers, Testing <strong>of</strong> towers,<br />

vibration studies on transmission line conductors and accessories, evaluation <strong>of</strong><br />

dampers etc.;<br />

- HVDC simulation and Transient Network Analyser (TNA) studies for power<br />

system planning <strong>of</strong> AC and DC networks, consultancy work for electricity boards<br />

and others<br />

- Investigation <strong>of</strong> problems connected with power systems, design and operation;<br />

- Development & testing <strong>of</strong> dielectrics, study <strong>of</strong> water chemistry, coal and fly ash<br />

analysis for studying Thermal <strong>Power</strong> Station problems and testing <strong>of</strong> transformer<br />

oil, coal & water quality etc.;<br />

- Development <strong>of</strong> apparatus/gadgets/instruments for application in power system;<br />

- Development & testing <strong>of</strong> LV and HV switchgear circuit breakers, fuses etc.<br />

- Testing <strong>of</strong> domestic electric appliances, equipment enclosures (for IP testing &<br />

flame pro<strong>of</strong> testing), relays, batteries etc.;<br />

- Impulse current generator for testing zinc oxide lightening arresters upto 100<br />

KV, 150 KJ;<br />

- New Pollution laboratory;<br />

- Impulse dielectric tests on all electrical equipment upto 3 MV, 150 KJ;<br />

- Ion migration test facility;<br />

- Multi product calibration system for all electrical measuring instruments;<br />

- Refrigerator & temperature bath test facility; and<br />

- All tests on energy meters.<br />

7.1.3 UNIQUE TESTS CARRIED OUT IN CPRI<br />

Accuracy test on CTs & PTs at Sharavathy Generating Station, Jog Falls<br />

The Short Circuit Laboratory <strong>of</strong> CPRI, Bangalore undertook the testing <strong>of</strong> 220 kV CTs<br />

(outdoor) and 11 kV Generator CTs & PTs at the Sharavathy Generating Station, Jog<br />

Falls on the request <strong>of</strong> Karnataka <strong>Power</strong> Corporation Ltd. The test arrangements were<br />

carefully planned in view <strong>of</strong> impending monsoon and the requirement <strong>of</strong> shutdown <strong>of</strong><br />