18.08.2013 Views

ClearPath OS 2200 Series Release 13.2 Software Planning and ...

ClearPath OS 2200 Series Release 13.2 Software Planning and ...

ClearPath OS 2200 Series Release 13.2 Software Planning and ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

General Exec Considerations<br />

4.1. General Exec Considerations<br />

This subsection identifies general Exec migration <strong>and</strong> compatibility considerations by<br />

software release level.<br />

<strong>Software</strong> <strong>Release</strong> Subsection<br />

<strong>ClearPath</strong> <strong>OS</strong> <strong>2200</strong> <strong>Release</strong> 13.1 4.1.1<br />

<strong>ClearPath</strong> <strong>OS</strong> <strong>2200</strong> <strong>Release</strong> 13.0 4.1.2<br />

<strong>ClearPath</strong> <strong>OS</strong> <strong>2200</strong> <strong>Release</strong> 12.1 4.1.3<br />

<strong>ClearPath</strong> <strong>OS</strong> <strong>2200</strong> <strong>Release</strong> 12.0 4.1.4<br />

Review the considerations for all releases higher than the release from which you are<br />

migrating.<br />

4.1.1. <strong>ClearPath</strong> <strong>OS</strong> <strong>2200</strong> <strong>Release</strong> 13.1<br />

The Exec "IT" keyin is enhanced <strong>and</strong> modified to mini mize the customer confusion<br />

caused by incomplete documentation <strong>and</strong> inadequate console message descriptions.<br />

See PLE 18828324 for more specific details.<br />

1. Modifies the IT,TIMER logic to use the keyword "CLEAR" to clear the current<br />

disk timer values <strong>and</strong> set the system logic to use the default disk timer values.<br />

The keyin format is:<br />

"IT,TIMER CLEAR" <strong>and</strong> the response to this keyin is:<br />

DISK TIMER VALUES RESET TO DEFAULTS<br />

DISK IOP TIMEOUT VALUE IS 4 SECONDS.<br />

DISK H<strong>OS</strong>T TIMEOUT VALUE IS 6 TO 13 SECONDS.<br />

2. The IT,TAPTIM keyin is changed to echo the value entered if it is in the<br />

range of 12 through 300. If the value is a non-zero value less than 12, 12<br />

seconds is used. If the value is greater than 300, 300 seconds is used. The value<br />

of zero is not legal. CLEAR is used to reset the realtime values back to the<br />

default non-realtime values.<br />

3. The IT keyin to enable/disable the SCIOP internal traces is being modified to<br />

accept the ON, OFF, <strong>and</strong> STATUS options as defined for the original IT trace<br />

keyins.<br />

4–2 7831 0349–043