Ordinary Meeting <str<strong>on</strong>g>of</str<strong>on</strong>g> Council - <strong>18</strong> July <strong>2006</strong> 2 / 20<br />

2 Princes Street, Turramurra<br />

Item 2<br />

DA0190/06<br />

<strong>18</strong> July <strong>2006</strong><br />

materials or locati<strong>on</strong> within the road reserve regardless <str<strong>on</strong>g>of</str<strong>on</strong>g> whether this informati<strong>on</strong> is<br />

shown <strong>on</strong> the applicati<strong>on</strong> documents.<br />

Note 1:<br />

Note 2:<br />

The c<strong>on</strong>structi<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> footpaths and driveways outside the property, in materials<br />

other than those approved by Council, is not permitted and Council may require<br />

immediate removal <str<strong>on</strong>g>of</str<strong>on</strong>g> unauthorised installati<strong>on</strong>s.<br />

When completing the request for driveway levels applicati<strong>on</strong> from Council, the<br />

applicant must attach a copy <str<strong>on</strong>g>of</str<strong>on</strong>g> the relevant Development Applicati<strong>on</strong> drawing<br />

which indicates the positi<strong>on</strong> and proposed level <str<strong>on</strong>g>of</str<strong>on</strong>g> the proposed driveway at the<br />

boundary alignment. Failure <str<strong>on</strong>g>to</str<strong>on</strong>g> submit this informati<strong>on</strong> may delay processing.<br />

35. Prior <str<strong>on</strong>g>to</str<strong>on</strong>g> issue <str<strong>on</strong>g>of</str<strong>on</strong>g> the C<strong>on</strong>structi<strong>on</strong> Certificate and prior <str<strong>on</strong>g>to</str<strong>on</strong>g> commencement <str<strong>on</strong>g>of</str<strong>on</strong>g> any works that<br />

may <str<strong>on</strong>g>be</str<strong>on</strong>g> subject <str<strong>on</strong>g>to</str<strong>on</strong>g> erosi<strong>on</strong>, the applicant must submit, for approval by the Principal Certifying<br />

Authority, a Soil and Erosi<strong>on</strong> C<strong>on</strong>trol Plan prepared in accordance with the Landcom<br />

document “Managing Urban S<str<strong>on</strong>g>to</str<strong>on</strong>g>rmwater – Soils and C<strong>on</strong>structi<strong>on</strong>, Volume 1” (2004) . A<br />

qualified and experienced civil/envir<strong>on</strong>mental engineer shall prepare this plan in accordance<br />

with the above guidelines and secti<strong>on</strong> 8.2.1 <str<strong>on</strong>g>of</str<strong>on</strong>g> Councils Water Management Development<br />

C<strong>on</strong>trol Plan 47.<br />

36. Prior <str<strong>on</strong>g>to</str<strong>on</strong>g> issue <str<strong>on</strong>g>of</str<strong>on</strong>g> the C<strong>on</strong>structi<strong>on</strong> Certificate the applicant must submit, for approval by the<br />

Principal Certifying Authority, scale c<strong>on</strong>structi<strong>on</strong> plans and specificati<strong>on</strong>s in relati<strong>on</strong> <str<strong>on</strong>g>to</str<strong>on</strong>g> the<br />

s<str<strong>on</strong>g>to</str<strong>on</strong>g>rmwater management and disposal system for the development. The plan(s) must include<br />

the following detail:<br />

Exact locati<strong>on</strong> and reduced level <str<strong>on</strong>g>of</str<strong>on</strong>g> discharge point <str<strong>on</strong>g>to</str<strong>on</strong>g> the public drainage system.<br />

Layout <str<strong>on</strong>g>of</str<strong>on</strong>g> the property drainage system comp<strong>on</strong>ents, including but not limited <str<strong>on</strong>g>to</str<strong>on</strong>g> (as required)<br />

gutters, downpipes, pits, grated drains, swales, kerbs, flushing facilities, subsoil drainage and<br />

all ancillary plumbing - all designed for a 235mm/hour rainfall intensity for a durati<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> five<br />

(5) minutes (1:50 year s<str<strong>on</strong>g>to</str<strong>on</strong>g>rm recurrence).<br />

Details <str<strong>on</strong>g>of</str<strong>on</strong>g> any required <strong>on</strong>-site detenti<strong>on</strong> tanks required under Ku-ring-gai Council Water<br />

Management DCP 47 including dimensi<strong>on</strong>s, materials, locati<strong>on</strong>, orifice and discharge c<strong>on</strong>trol<br />

pit details as required (refer chapter 6 and appendices 2, 3 and 5 for volume, PSD and design<br />

requirements).<br />

The above c<strong>on</strong>structi<strong>on</strong> drawings and specificati<strong>on</strong>s are <str<strong>on</strong>g>to</str<strong>on</strong>g> <str<strong>on</strong>g>be</str<strong>on</strong>g> prepared by a suitably qualified<br />

and experienced civil/hydraulic engineer in accordance with Councils Water Management<br />

Development C<strong>on</strong>trol Plan 47, Australian Standards 3500.2 and 3500.3 - Plumbing and<br />

Drainage Code and the BCA. The plans may <str<strong>on</strong>g>be</str<strong>on</strong>g> generally based up<strong>on</strong> the S<str<strong>on</strong>g>to</str<strong>on</strong>g>rmwater<br />

Drainage Plan 4030 OSD-1 A prepared by Mepstead & Associates submitted for<br />

Development Applicati<strong>on</strong> approval, which are <str<strong>on</strong>g>to</str<strong>on</strong>g> <str<strong>on</strong>g>be</str<strong>on</strong>g> advanced as necessary for c<strong>on</strong>structi<strong>on</strong><br />

issue purposes.<br />

C<strong>on</strong>diti<strong>on</strong>s <str<strong>on</strong>g>to</str<strong>on</strong>g> <str<strong>on</strong>g>be</str<strong>on</strong>g> complied with Prior <str<strong>on</strong>g>to</str<strong>on</strong>g> Occupati<strong>on</strong><br />

37. Following completi<strong>on</strong>, installati<strong>on</strong> and testing <str<strong>on</strong>g>of</str<strong>on</strong>g> all mechanical ventilati<strong>on</strong> equipment and<br />

acoustic treatment(s), the applicant shall provide evidence <str<strong>on</strong>g>to</str<strong>on</strong>g> the satisfacti<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> the Principal<br />

N:\0607<strong>18</strong>-OMC-PR-03466-2 PRINCES STREET TURRAMUR.doc/nrichter/20