16-66 ELECTRICAL SYSTEM<br />

Meter, Gauge, Indicator Unit<br />

Electronic Combination Meter Unit Inspection<br />

• Remove the meter unit [A].<br />

[1] Ignition [10] Battery (+)<br />

[2] Fuel Reserve Switch [11] Oil Pressure Warning<br />

[3] Unused Indicator Light (LED)<br />

[4] Fuel Level Sensor Ground (–)<br />

[5] Neutral Indicator Light [12] Speed Sensor Supply<br />

(LED) Ground (–) Voltage<br />

[6] FI Indicator Light [13] Right Turn Signal Light<br />

(LED) Ground (–) (LED) (+)<br />

[7] Tachometer Pulse [14] Left Turn Signal Indicator<br />

[8] Water Temperature Light (LED) (+)<br />

Sensor<br />

[15] High Beam Indicator Light<br />

[9] Ground (–) (LED)<br />

[16] Speed Sensor Pulse<br />

CAUTION<br />

Do not drop the meter unit. Place the meter unit so<br />

that it faces upward. If the meter unit is left upside<br />

down or sideways for a long time or dropped, it will<br />

malfunction. Do not short each terminals.<br />

Liquid Crystal Display (LCD) Segments Check:<br />

• Use the harness adapter for meter inspection.<br />

Special Tool - Harness Adapter : 57001–1542<br />

• Using the auxiliary wires, connect the 12 V battery to the<br />

meter unit connector as follows.<br />

○Connect the battery positive terminal to the terminal [10].<br />

○Connect the battery negative terminal to the terminal [9].<br />

• Connect the terminal [1] to the terminal [10].<br />

○The tachometer LCD segments momentarily to it last<br />

readings two times and segment movement is reversal.<br />

○When the terminals are connected, all the LCD segments<br />

[A] and LED warning light [B] appear for three seconds.<br />

If the LCD segments and LED warning light will not appear,<br />

replace the meter assembly.<br />

• Disconnect the terminal [1].<br />

○All the LCD segments and LED warning light disappear.<br />

If the segments do not disappear, replace the meter assembly.<br />