Chapter 6Setting up parameters<br />
[Parameter <strong>mode</strong>]<br />
Error count cleared by S-ON<br />
(<strong>position</strong> <strong>mode</strong>)<br />
Function<br />
Even when the servo power is OFF, the control power is<br />
still ON. If the <strong>position</strong> of the load mechanism shifts due to<br />
gravity or manual force while the servo power is OFF, the<br />
error count changes. If the servo power is turned ON, the<br />
actuator rotates rapidly to make the error count return to<br />
[0].<br />
This rapid motion may be dangerous. The S-ON function<br />
allows the error count to be reset to [0] when the servo<br />
power is turned on. Thus, the actuator will not move when<br />
the servo power is restored. However, the <strong>position</strong> error<br />
data is lost and the actuator will not return to its original<br />
<strong>position</strong>.<br />
Details of display<br />
1st digit: [5:error count cleared by S-ON]<br />
2nd to 5th digit: No indication<br />
6th digit: indicates current setting of [error count<br />
cleared by S-ON].<br />
[0]: not cleared<br />
[1]: cleared<br />
Operations<br />
(1) To change a value, press the [ADJ] key at least 0.1 second.<br />
1st digit [5] flashes. You can change the value<br />
(2) Set [0] (not cleared) by the [DOWN] key, or set [1] (cleared) by [UP] key.<br />
(3) To define the new value, press the [SET] key at least 0.1 second.<br />
Flashing of 1st digit [5] stops and the new value is defined.<br />
1st digit<br />
(4) To cancel a change in operation, press the [ADJ] key at least 0.1 second.<br />
Flashing of 1st digit [5] stops and the previous value becomes effective.<br />
6th digit<br />
U P D O W N A D J S E T<br />
Error count cleared by<br />
S-ON<br />
Indicate current setting of<br />
error count cleared by S-ON<br />
0: not cleared<br />
1: cleared<br />
- 107 -