Chapter 8 Options<br />
8-5 Isolation transformer<br />
u Models<br />
The <strong>mode</strong>l of the Isolation transformer is as<br />
follows:<br />
PT1-200 04-200<br />
Ins. transformer: PT1 series<br />
2nd volt. 200:<br />
2nd cur. 04: 4A<br />
08: 8A<br />
AC 200V<br />
Prim. volt 100: AC100V<br />
115: AC115V<br />
200: AC200V<br />
220: AC220V<br />
u Specifications<br />
The specifications of transformers are as follows:<br />
PT1-<br />
20004-XXX<br />
PT1-<br />
20008-XXX<br />
Rated 2nd voltage 200V 200V<br />
Rated 2nd current 4A 8A<br />
Rated prim. Volt. AC100/115/200/220V, 50/60Hz<br />
Rated capacity 800VA 1600VA<br />
Isolation class B-class Isolation<br />
Ins. resistance 500M ohm or more (DC 1000V)<br />
Withstand voltage AC2000V 1minute (50/60Hz)<br />
Amb. temperature 10 to +55<br />
Overheat protection Built-in thermal protector<br />
(cutoff temperature: 130)<br />
u External dimensions<br />
The external dimensions of the transformers are as follows:<br />
Third angle projection method <br />
Unit: mm<br />
Model A B C D E F<br />
PT1-20004 145 96 150 120 160 6.5<br />
PT1-20008 180 127 165 127 195 6.5<br />
Model G H J t Mass<br />
PT1-20004 4 120 140 1.6 7.5kg<br />
PT1-20008 4 150 155 2.3 14.5kg<br />
u Connections<br />
The schematic of the transformers are shown below in the figure to the left. When the primary voltage is<br />
one of 100/115/200/220V, connect terminals as shown below in the figures to the right.<br />
AC100V AC115V AC200V AC220V<br />
Power<br />
Power<br />
Power<br />
Power<br />
Primary<br />
Secondary<br />
- 143-