<strong>FS1</strong> <strong>Installation</strong> <strong>and</strong> <strong>Operation</strong> Manual — Front Panel<br />

Status Display Pressing the Status button under the <strong>AJA</strong> logo pages through the eight status<br />

displays. Normally, you'll be viewing the main status screen shown in a previous<br />

illustration. It’s the default screen at powerup. Information contained in the<br />

status display shows the current primary settings for the <strong>FS1</strong>:<br />

• Input Format (upper left)<br />

• Output Format (lower left)<br />

• Selected Video Input setting (upper right)<br />

• Selected Audio Input setting (lower right)<br />

Input Format Video Input setting<br />

Output Format Audio Input setting<br />

For example, if set up to do a cross-convert from 1080i59.94 to 720p59.94<br />

using embedded audio in <strong>and</strong> out, the display would look as follows:<br />

IN 1080i59.94 SDI 1<br />

OUT 720p59.94 SDI 1<br />

If the selected input has no valid signal present, the <strong>FS1</strong> displays IN No Input.<br />

Note: If the input is incompatible with the chosen output format, the default<br />

status screen will display the actual format, such as IN 525i 59.94. The video<br />

format status screen, however, would be the default status screen at that point<br />

(since the Alarm LED would be on), <strong>and</strong> it would display IN Incompat.<br />

The other seven status displays are listed <strong>and</strong> described below:<br />

The video format status screen shows the status of the active video input, the<br />

output format, the genlock source, <strong>and</strong> the format of the reference signal (if<br />

applicable). For example, if the Output Format is set to Follow REF, but<br />

there is no valid reference signal present, the Output Format section of the<br />

video format status screen will read OUT No Ref.<br />

The sidebar status screen shows the main input format, sidebar input format,<br />

output format, <strong>and</strong> sidebar input select. Any incompatibilities between<br />

these formats are shown as Incompat.<br />

The sidebar input screen always shows the detected formats of the main input<br />

<strong>and</strong> the sidebar input—to help resolve incompatibilities.<br />

The power/temperature status screen displays power supply <strong>and</strong> temperature<br />

status. If a power supply is unplugged or an error is detected, the display top<br />

line reads PS 1 OFF, PS 2 OFF, PS 1 Error, or PS 2 Error, respectively.<br />

(When Power Supply Alarm filter (60.1) is set to Suppress; the display still<br />

reads Power OK even if a power supply is unplugged.) If the <strong>FS1</strong> internal<br />

temperature threshold is exceeded, the display lower line reads<br />

OVERHEATED <strong>and</strong> video output may be compromised. If the front panel<br />

Alarm LED is lit, the reason should be evident if you check the video format<br />

<strong>and</strong> power/temperature status screens.<br />