4. INTERFACE BETWEEN NC AND PMC B–<strong>62755EN</strong>/01 ANALYS screen(Ladder editing card isrequired for PMC–RB5/RB6)Change of signals is displayed as the same display as that on theoscilloscope.1 Parameter setting screen (1st page)PMC SIGNAL ANALYSIS(PARAM)MONIT RUNSAMPLING TIME : 10 (1–10 SEC)TRIGGER ADDRESS : G0007.2CONDITION : 0(0: START 1: TRIGGER–ON 2: TRIGGER–OFF)TRIGGER MODE : 0(0: AFTER 1: ABOUT 2: BEFORE 3: ONLY)SCOPEDELETEINITADDRESSSelect each item bycursor key(a) Set a sampling time.(b)Specifies an address from which recording of signals is started.(c) Set a condition under which recording is initiated.0 : Started by soft key [START]1 : Started by rise of a trigger signal after you press the soft key[START]2 : Started by fall of a trigger signal after you press the soft key[START](d)Set a trigger mode0 : Record signal status after the trigger condition is satisfied1 : Record signal status before and after the trigger condition issatisfied.2 : Record signal status before the trigger condition is satisfied.3 : Record signal status when the trigger condition is satisfied.(Display is same as trace memory).228