1. DISPLAY AND OPERATION OF CRT/MDI B–<strong>62755EN</strong>/01Pressing the [SATART] soft key starts data sampling. While samplingis being performed, SAMPLING blinks at the top of the screen. Once datasampling has been completed, a waveform is automatically displayed.WAVE DIAGNOS. (GRAPHIC)CH1O1234 N12345CH2EDIT **** ******[START] [TIME] [TIME] [H–DOBL] [H–HALF] Drawing a waveform forstorage type waveformdiagnosisTo use storage type waveform diagnosis, set 100 for the display startcondition. The maximum data width for storage type waveform diagnosisis 32760 ms. Data must be sampled before starting drawing. The nextpage explains sampling in detail.Pressing the [START] soft key loads stored data. While the data is beingloaded, SAMPLING blinks at the top of the screen. Once the data hasbeen loaded, a waveform is displayed. The date on which the data wasstored is displayed at the top left of the screen. If the [START] soft keyis pressed while data is being stored, storage is stopped and the waveformfor the data stored up to that point is displayed. The WAVE DIAGNOS.(MOMORY) screen indicates whether data is being stored.WAVE DIAGNOS. (GRAPHIC)CH193/01/13 12:15:00O1234 N12345CH2EDIT **** ******[START] [TIME] [TIME] [H–DOBL] [H–HALF]74