B–<strong>62755EN</strong>/01APPENDIXB. ALARM LISTB.2LIST OF ALARMS(PMC)(1) Alarm messages (PMC)MessageContents and solutionALARM NOTHINGER00 PROGRAM DATAERROR(ROM)ER01 PROGRAM DATAERROR(RAM)ER02 PROGRAM SIZE OVERER03 PROGRAM SIZEERROR(OPTION)ER04 PMC TYPE UNMATCHER05 PMC MODULE TYPEERRORER06 PROGRAM MODULENOTHINGER07 NO OPTION(LADDER STEP)ER <strong>16</strong> RAM CHECK ERROR(PROGRAM RAM)ER17 PROGRAM PARITYER<strong>18</strong> PROGRAM DATA ERRORBY I/OER19 LADDER DATA ERRORER20 SYMBOL/COMMENTDATA ERRORNormal statusThe sequence program in the ROM is not written correctly.(solution) Please exchange ROM for the sequence program.The sequence program in the debugging RAM is defective.(solution) Please clear the debugging RAM and input LADDER again.The debugging RAM is not installed though the RAM is selected.(solution) Please install the debugging RAM or install ROM for sequence programand select ROM with K17#3=0.The size of sequence program exceeds the maximum size of LADDER(PMC–RC only).(solution) Please change MAX LADDER AREA SIZE at the SYSPRM screen andrestart the system.The size of sequence program exceeds the option specification size.(solution) Please increase the option specification size.Or, reduce the size of sequence program.The PMC model setting of the sequence program is not corresponding to an actual model.(solution) Please change the PMC model setting by the offline programmer.The module type of the PMC engine is not correct.(solution)Please exchange the module of PMC engine for a correct one.Both ROM for sequence program and the debugging RAM do not exist (PMC–RC only)There is no step number option of LADDER.The debugging RAM cannot be read/written normally.(solution) Please exchange the debugging RAM.The parity error occurred on ROM for sequence program or the debugging RAM.(solution) ROM: The deterioration of ROM may be deterioratedPlease exchange ROM for the sequence programRAM: Please edit the sequence program once on PMCStill the error occurs, exchange the debugging RAM.Transferring the sequence program from offline programmer was interrupted by thepower off etc.(solution) Please clear the sequence program and transfer the sequence programagain.Editing the LADDER was interrupted by the power off or by the switch to the CNC screenby the function key etc.(solution) Please edit LADDER once on PMC.Or, please input LADDER again.Editing the symbol and comment was interrupted by the power off or by the switch to theCNC screen by the function key etc.(solution) Please edit symbol and comment once on PMC.Or, please input symbol and comment again.447

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!