10.07.2015 Views

Series 16/18/160/180-Model C Maintenance Manual, GFZ-62755EN ...

Series 16/18/160/180-Model C Maintenance Manual, GFZ-62755EN ...

Series 16/18/160/180-Model C Maintenance Manual, GFZ-62755EN ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

B. ALARM LIST APPENDIXB–<strong>62755EN</strong>/01MessageILLEGAL FUNCTION NO.FUNCTION LINE ILLEGALHORIZONTAL LINE ILLEGALILLEGAL NET CLEAREDILLEGAL OPERATIONSYMBOL UNDEFINEDINPUT INVALIDNET TOO LARGEJUMP FUNCTION MISSINGLADDER BROKENLADDER ILLEGALIMPOSSIBLE WRITEOBJECT BUFFER OVERPARAMETER NOTHINGPLEASE COMPLETE NETPLEASE KEY IN SUB NO.PROGRAM MODULE NOTHINGRELAY COIL FORBITRELAY OR COIL NOTHINGPLEASE CLEAR ALLSYMBOL DATA DUPLICATECOMMENT DATA OVERFLOWContents and solutionThe wrong number of the functional instruction is searched.The functional instruction is not correctly connected.The horizontal line of the net is not connected.Because the power had been turn off while editing LADDER, some net under editingwas cleared.Operation is not correct.The value is not specified and only INPUT key was pushed.The address data is not correctly inputted.Because the space to display the instruction on screen is not enough, the functionalinstruction cannot be made.The symbol which was inputted is not defined.There is an incorrect input data.Non–numerical value was inputted with COPY, INSLIN,C–UP,C–DOWN etc.The input address was specified for write coil.An illegal character was specified for the data table.The input net is larger than the editing buffer.(solution) Please reduce the net under editing.The functional instruction JMP(SUB10) is not correctly dealt with.Correspondence of JMP and JMPE(SUB30) is incorrect.The number of coil to jump is specified by the model which the number of coil cannotspecified. (It is possible to specify the coil number only on PMC–RB/RC.)LADDER is broken.There is an incorrect LADDER.You try to edit sequence program on the ROM.The sequence program area was filled.(solution) Please reduce the LADDER.There is no parameter of the functional instruction.The error net was found in LADDER.(solution) After correcting the error net, please continue operating.Please input the number of the functional instruction.(solution) If you do not input the functional instruction, please push soft key “FUNC”again.You tried to edit though there was neither RAM for debugging nor ROM for sequenceprogram.There is an unnecessary relay or coil.The relay or the coil does not suffice.It is impossible to recover the sequence program.(solution) Please clear the all data.The same symbol name is defined in other place.The comment data area was filled.(solution) Please reduce the number of the commnet.452

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!