10.07.2015 Views

Series 16/18/160/180-Model C Maintenance Manual, GFZ-62755EN ...

Series 16/18/160/180-Model C Maintenance Manual, GFZ-62755EN ...

Series 16/18/160/180-Model C Maintenance Manual, GFZ-62755EN ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

B–<strong>62755EN</strong>/01APPENDIXB. ALARM LISTNumberMessageContents5063 IS NOT PRESET AFTER REF.(M series)5064 DIFFERRENT AXIS UNIT (IS–B,IS–C)(M series)5065 DIFFERENT AXIS UNIT (PMC AXIS)(M series)5066 RESTART ILLEGAL SEQUENCENUMBER(M series)5068 G31 P90 FORMAT ERROR(M series)Function category:Workpiece thickness measurementAlarm detailsThe position counter was not preset before the start of workpiece thicknessmeasurement. This alarm is issued in the following cases:(1) An attempt has been made to start measurement without first establishingthe origin.(2) An attempt has been made to start measurement without first presettingthe position counter after manual return to the origin.Circular interpolation has been specified on a plane consisting of axeshaving different increment systems.Axes having different increment systems have been specified in thesame DI/DO group for PMC axis control. Modify the setting of parameterNo. 8010.Sequence number 7xxx has been read during search for the next sequencenumber at program restart for the return/restart function.No movement axis or more than one movement axis has been specified.5073 NO DECIMAL POINT No decimal point has been specified for an address requiring a decimalpoint.5074 ADDRESS DUPLICATION ERROR The same address has been specified two or more times in a singleblock. Alternatively, two or more G codes in the same group have beenspecified in a single block.5082 DATA SERVER ERROR This alarm is detailed on the data server message screen.NOTEHPCC : High precision contour control(2) Background edit alarmNumber Message Contents??? BP/S alarm BP/S alarm occurs in the same number as the P/S alarm that occurs inordinary program edit. (070, 071, 072, 073, 074 085,086,087 etc.)140 BP/S alarm It was attempted to select or delete in the background a program beingselected in the foreground. (Note)Use background editing correctly.NOTEAlarm in background edit is displayed in the key input line of the background edit screen insteadof the ordinary alarm screen and is resettable by any of the MDI key operation.437

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!