10.07.2015 Views

Series 16/18/160/180-Model C Maintenance Manual, GFZ-62755EN ...

Series 16/18/160/180-Model C Maintenance Manual, GFZ-62755EN ...

Series 16/18/160/180-Model C Maintenance Manual, GFZ-62755EN ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

4. INTERFACE BETWEEN NC AND PMC B–<strong>62755EN</strong>/01k0<strong>18</strong>#7#6 #5 #4 #3 #2 #1 #0ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ#7(IGNDINT)ÀÀÀÀ#5(CHKPRTY)#4(CALCPRTY)#3(TRNSRAM)#2(TRGSTAT)0 : When the screen is switched to the PCMMDI screen, the CRT is initialized.ÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀÀ1 : When the screen is switched to the PCMMDI screen, the CRT is notinitialized.*It is effective for PMC–RC3/RC40 : The parity check is performed for the system ROM and programROM/RAM.1 : The parity check is not performed for the system ROM and programROM/RAM.0 : The built–in programmer function performs RAM parity calculation.1 : The built–in programmer function does not perform RAM paritycalculation.0 : A ladder program is not automatically sent to the backup RAM afteron–line editing is completed.1 : A ladder program is automatically sent to the backup RAM after on–lineediting is completed.0 : The trigger stop function does not automatically start when the power isturned on.1 : The trigger stop function automatically starts when the power is turned on.#1(DBGSTAT) 0: In the C language debug function, the automatic break processingdoes not start when the power is turned on.1 : In the C language debug function, the automatic break processingstarts when the power is turned on.*This flag is effective for the PMC–RC3/RC4.#0(IGNKEY)0 : Function keys are enabled when a user program displays the userscreen.1 : Function keys are disabled when a user program displays the userscreen.*This flag is effective for the PMC–RC3/RC4.When this bit is set to 1 of the user screen, the screen cannot be switch tothe NC screen using function keys. A program which always sets this bitto 0 or which changes the screen to the NC screen is required.k019#7#6 #5 #4 #3 #2 #1 #0#1(C–REJECT)0 : A C–language program is activated.ÀÀÀÀÀÀ1 : A C–language program is forcibly activated.*The flag is effective for the PMC–RC3/RC4.These bits are status of not used for PMC management software are usedby system. Do not change the values.Usually all the bits are 0.234

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!