10.07.2015 Views

Series 16/18/160/180-Model C Maintenance Manual, GFZ-62755EN ...

Series 16/18/160/180-Model C Maintenance Manual, GFZ-62755EN ...

Series 16/18/160/180-Model C Maintenance Manual, GFZ-62755EN ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

B–<strong>62755EN</strong>/011. DISPLAY AND OPERATION OF CRT/MDI1.6.3Setting The InputSignal or Output Signalto Be Recorded in TheOperation History(1)On the operation history signal selection screen, press the [(OPE)] softkey.OP_HIS SIGNAL SELECTO1000 N02000No. ADDRES SIGNAL No. ADDRES SIGNAL01 G0004 00000010 11 ********02 ******** 12 ********03 ******** 13 ********04 ******** 14 ********05 ******** 15 ********06 ******** <strong>16</strong> ********07 ******** 17 ********08 ******** <strong>18</strong> ********09 ******** 19 ********10 ******** 20 ********>EDIT **** *** *** *** 00:00:00[ ALLDEL ][ DELETE ][ ON:1 ][ OFF:0 ][ ](2)Press the cursor key or to position the cursor to a desiredposition.(3)Key in a signal type (X, G, F, or Y) and an address, then press the INPUTkey.Example)G0004 INPUTSignal address G0004 is set in the ADDRES column. Thecorresponding position in the SIGNAL column is initialized to000000000.(4)Select the bit to be recorded.To select all bits of the specified signal address, press the [ON:1] softkey while the cursor is positioned to 00000000 .To select a particular bit, position the cursor to that bit by pressing thecursor key or , then press the [ON:1] soft key. To cancela selection made by pressing the [ON:1] soft key or to cancel apreviously selected signal, press the [OFF:0] soft key.(5)Up to 20 addresses can be specified by means of this signal selection.These addresses need not always be specified at consecutive positions,starting from No.1.(6)Pressing the [ALLDEL] and [EXEC] soft keys deletes all data. If the[ALLDEL] key is pressed by mistake, it can be cancelled by pressingthe [CAN] key.(7)To delete a selected signal address, position the cursor to thecorresponding position then press the [DELETE] and [EXEC] softkeys. In the SIGNAL column, asterisks ******** are displayed inplace of the deleted data. In the ADDRES column, the correspondingposition is cleared.If the [DELET] key is pressed by mistake, it can be cancelled bypressing the [CAN] key.35

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!