B–<strong>62755EN</strong>/011. DISPLAY AND OPERATION OF CRT/MDIMode selection signals and rapid traverse override signalsare displayed as indicated below:Input signalMD1 ND2 MD4 REF DNC1Name displayed0 0 0 0 0 MDI1 0 0 0 0 MEM1 0 0 0 1 RMT0 1 0 0 0 NOMODE1 1 0 0 0 EDT0 0 1 0 0 H/INC1 0 1 0 0 JOG1 0 1 1 0 REF0 1 1 0 0 TJOG1 1 1 0 0 THNDInput signalRV1RV2Name displayed0 0 R 100%1 0 R 50%0 1 R 25%1 1 R F0%(3)NC alarmsNC alarms are displayed in reverse video.P/S alarms, system alarms, and external alarms are displayed togetherwith their numbers.For other types of alarms, only the alarm type is displayed. (No detailsare displayed.)For two–path control, the operations of path 2 are displayed in thesame way, but preceded by S_.Example) P/S0050, SV_ALM, S_APC_ALM(4)Time stamp (date and time)The following time data (date and time) is recorded:1) Date and time of power–on2) Date and time of power–off3) Date and time when an NC alarm occurs4) The clock time is recorded at predetermined intervals, togetherwith each new calendar day.33