B. ALARM LIST APPENDIXB–<strong>62755EN</strong>/01NumberMessageContents764 SPINDLE–2 ABNORMAL TORQUE Same as alarm No. 754 (for the second spindle)ALM771 SPINDLE–3 ALARM DETECT Same as alarm No. 751 (for the third spindle)(AL–XX)772 SPINDLE–3 MODE CHANGE EROR Same as alarm No. 752 (for the third spindle)774 SPINDLE–3 ABNORMAL TORQUEALMSame as alarm No. 754 (for the third spindle) The details of spindlealarm No.750The details of spindle alarm No. 750 are displayed in the diagnosis display(No. 409) as shown below.409#7#6 #5 #4 #3SPE#2S2E#1S1E#0SHE(10)Safety zone alarms#3 (SPE) 0 : In the spindle serial control, the serial spindle parameters fulfill thespindle unit startup conditions.1 : In the spindle serial control, the serial spindle parameters do not fulfillthe spindle unit startup conditions.#2 (S2E) 0 : The second spindle is normal during the spindle serial control startup.1 : The second spindle was detected to have a fault during the spindleserial control startup.#1 (S1E) 0 : The first spindle is normal during the spindle serial control startup.1 : The first spindle was detected to have a fault during the spindle axisserial control startup.#0 (SHE) 0 : The serial communications module in the CNC is normal.1 : The serial communications module in the CNC was detected to have afault.Number Message Contents4800 ZONE : PUNCHING INHIBITED 1 When a safety zone check was executed, a punch command wasspecified in area 1 where punching is inhibited.4801 ZONE : PUNCHING INHIBITED 2 When a safety zone check was executed, a punch command wasspecified in area 2 where punching is inhibited.4802 ZONE : PUNCHING INHIBITED 3 When a safety zone check was executed, a punch command wasspecified in area 3 where punching is inhibited.4803 ZONE : PUNCHING INHIBITED 4 When a safety zone check was executed, a punch command wasspecified in area 4 where punching is inhibited.4810 ZONE : ENTERING INHIBITED 1 +X When a safety zone check was executed, the machine moving in thepositive X direction entered area 1 into which entry is inhibited.4811 ZONE : ENTERING INHIBITED 1–XWhen a safety zone check was executed, the machine moving in thenegative X direction entered area 1 into which entry is inhibited.4812 ZONE : ENTERING INHIBITED 2 +X When a safety zone check was executed, the machine moving in thepositive X direction entered area 2 into which entry is inhibited.4813 ZONE : ENTERING INHIBITED 2–XWhen a safety zone check was executed, the machine moving in thenegative X direction entered area 2 into which entry is inhibited.444

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!