10.07.2015 Views

Series 16/18/160/180-Model C Maintenance Manual, GFZ-62755EN ...

Series 16/18/160/180-Model C Maintenance Manual, GFZ-62755EN ...

Series 16/18/160/180-Model C Maintenance Manual, GFZ-62755EN ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

B–<strong>62755EN</strong>/01APPENDIXB. ALARM LISTNumberMessageContents083ILLEGAL AXIS COMMAND IN G37(M series)ILLEGAL AXIS COMMAND IN G37(T series)In automatic tool length measurement, an invalid axis was specified orthe command is incremental. Modify the program.In automatic tool compensation (G36, G37), an invalid axis was specifiedor the command is incremental. Modify the program.085 COMMUNICATION ERROR When entering data in the memory by using Reader / Puncher interface,an overrun, parity or framing error was generated. The number of bitsof input data or setting of baud rate or specification No. of I/O unit is incorrect.086 DR SIGNAL OFF When entering data in the memory by using Reader / Puncher interface,the ready signal (DR) of reader / puncher was turned off.Power supply of I/O unit is off or cable is not connected or a P.C.B. is defective.087 BUFFER OVERFLOW When entering data in the memory by using Reader / Puncher interface,though the read terminate command is specified, input is not interruptedafter 10 characters read. I/O unit or P.C.B. is defective.088 LAN FILE TRANS ERROR(CHANNEL–1)089 LAN FILE TRANS ERROR(CHANNEL–2)090 REFERENCE RETURNINCOMPLETE091 REFERENCE RETURNINCOMPLETE092 AXES NOT ON THE REFERENCEPOINT094 P TYPE NOT ALLOWED(COORD CHG)095 P TYPE NOT ALLOWED(EXT OFS CHG)096 P TYPE NOT ALLOWED(WRK OFS CHG)097 P TYPE NOT ALLOWED(AUTO EXEC)098 G28 FOUND IN SEQUENCERETURN099 MDI EXEC NOT ALLOWEDAFT. SEARCHFile data transfer via OSI–ETHERNET has been stopped due to a transfererror.File data transfer via OSI–ETHERNET has been stopped due to a transfererror.The reference position return cannot be performed normally becausethe reference position return start point is too close to the reference positionor the speed is too slow. Separate the start point far enough fromthe reference position, or specify a sufficiently fast speed for referenceposition return. Check the program contents.<strong>Manual</strong> reference position return cannot be performed when automaticoperation is halted.The commanded axis by G27 (Reference position return check) did notreturn to the reference position.P type cannot be specified when the program is restarted. (After the automaticoperation was interrupted, the coordinate system setting operationwas performed.)Perform the correct operation according to th operator’s manual.P type cannot be specified when the program is restarted. (After theautomatic operation was interrupted, the external workpiece offsetamount changed.)Perform the correct operation according to th operator’s manual.P type cannot be specified when the program is restarted. (After the automaticoperation was interrupted, the workpiece offset amountchanged.)Perform the correct operation according to the operator’s manual.P type cannot be directed when the program is restarted. (After powerON, after emergency stop or P / S 94 to 97 reset, no automatic operationis performed.) Perform automatic operation.A command of the program restart was specified without the referenceposition return operation after power ON or emergency stop, and G28was found during search.Perform the reference position return.After completion of search in program restart, a move command is givenwith MDI. Move axis before a move command or don’t interrupt MDI operation.100 PARAMETER WRITE ENABLE On the PARAMETER(SETTING) screen, PWE(parameter writing enabled)is set to 1. Set it to 0, then reset the system.425

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!