Servicing Cylindrical Parts4. Connect the motor connector:a. From the inside of the door, connect the motor connector fromthe chassis to its mating connector on the wire harness.Wire connectionMotorColorsYellowGrayNo. of No. ofwires pins2 2Note: The upgrade cable is used for upgrading the lock withoutremoving the lock from the door. This cable does not connect toa mating lock connector.CautionWhen connecting the motor connector, make sure:■ there are no loose wire connections where the wires are insertedinto the connectors■ the connectors are firmly mated.Upgrade cable – not connectedMotor connectorInside of doorFigure 7.14Connecting the motor connectorB.A.S.I.S. G <strong>Service</strong> <strong>Manual</strong> 7–11