Servicing Standard Mortise Case Parts7. Insert the motor module’s actuator into the opening in the lockingbar. See Figure 6.5. Rotate the components into place. The motormodule locks into place in the case. The locking bar fits into the sloton the outside hub. The two feet on the bottom of the locking barfit into the bottom of the case.Outside hubLocking barMotor module’sactuatorFigure 6.5Motor module and locking bar in placeTurning over the cylinder clamp plateTurn over the cylinder clamp plate and insert it in the case.See Figure 6.4.Note: The screw must be on the same side of the case as the cylinder.B.A.S.I.S. G <strong>Service</strong> <strong>Manual</strong> 6–7