2 Machine- and Setting Data <strong>11</strong>.032.2 Drive machine data1342 SAFE_POS_TOL CR: / FBSI /D07 Actual value tolerance for the cross-check (not 810D) FDD/MSD ROT/LIN 2/4 840Dum, mDegrees 100 1 360000 DWORD PowerOn1344 SAFE_REFP_POS_TOL CR: FBSID07Actual value tolerance safe axis position MSD SLM FDD 2/4µm, mdegreesHW:P2 10 0 36000 DWORD Power On1344 SAFE_REFP_POS_TOL CR: / FBSI /D07 Actual value tolerance safe axis position (not 810D) FDD/MSD ROT/LIN 2/4 840Dum, mDegrees 10 0 36000 DWORD PowerOn1346 SAFE_VELO_X CR: FBSID07Speed limit nx MSD SLM FDD 2/4mm/min, rpmHW:P2 20.000000 0.000000 1000.000000 FLOAT Power On1346 SAFE_VELO_X CR: / FBSI /D07 Speed limit nx (not 810D) FDD/MSD ROT/LIN 2/4 840Dmm/min, rev/min 20.0000 0.0000 1000.0000 FLOAT PowerOn1348 SAFE_STOP_VELO_TOL CR: FBSID07Actual speed tolerance for SBR MSD SLM FDD 2/4mm/min, rpmHW:P2 300.000000 0.000000 20000.000000 FLOAT Power On1348 SAFE_STOP_VELO_TOL CR: / FBSI /D07 Actual speed tolerance for SBR (not 810D) FDD/MSD ROT/LIN 2/4 840Dmm/min, rev/min 300.0000 0.0000 20000.0000 FLOAT PowerOn1349 SAFE_SLIP_VELO_TOL CR: FBSID07Tolerance 2 encoder drift/slip MSD SLM FDD 2/4mm/min, rpmHW:P2 6.000000 0.000000 1000.000000 FLOAT Power On1349 SAFE_SLIP_VELO_TOL CR: / FBSI /D07 Tolerance 2 encoder drift/slip (not 810D) FDD/MSD ROT/LIN 2/4 840Dmm/min, rev/min 6.0000 0.0000 1000.0000 FLOAT PowerOn1350 SAFE_MODE_SWITCH_TIME CR: FBSID07Tolerance time for SGE changeover MSD SLM FDD 2/4msHW:P2 500.000000 0.000000 10000.000000 FLOAT Power On1350 SAFE_MODE_SWITCH_TIME CR: / FBSI /D07 Tolerance time for SGE changeover (not 810D) FDD/MSD ROT/LIN 2/4 840Dms 500.0000 0.0000 10000.0000 FLOAT PowerOn1351 SAFE_VELO_SWITCH_DELAY CR: FBSID07Delay time for SG changeover MSD SLM FDD 2/4msHW:P2 100.000000 0.000000 60000.000000 FLOAT Power On1351 SAFE_VELO_SWITCH_DELAY CR: / FBSI /D07 Delay time for SG changeover (not 810D) FDD/MSD ROT/LIN 2/4 840Dms 100.0000 0.0000 10000.0000 FLOAT PowerOn© Siemens AG, <strong>2003</strong>. All rights reserved2-102 SINUMERIK 840D/840Di/810D SIMODRIVE 6<strong>11</strong> digital <strong>Lists</strong> (LIS) – <strong>11</strong>.03 <strong>Edition</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!