12.07.2015 Views

Lists 11/2003 Edition

Lists 11/2003 Edition

Lists 11/2003 Edition

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2 Machine- and Setting Data <strong>11</strong>.032.2 Drive machine dataThe drive machine data, MSD, of the second motor are listed in the following.The cross-references correspond to those of the MD for the first motor with thecorresponding identifier.2005 ENC_RESOL_MOTOR_M2 CR: / /D06 Motor measuring system encoder increments (not 810D) MSD ROT 2/4 840D- 2048 1 65535 UNS. WORD PowerOn2098 INVERTER_MAX_CURR_DERAT_M2 CR: /DE1, DM1 /D05 PS derating limit current (not 810D) MSD ROT 2/4 840DA 200.0000 0.0000 500.0000 FLOAT Immediately2099 INVERTER_DERATING_FACT_M2 CR: /DE1, DM1 /D05 PS limit current derating (not 810D) MSD ROT 2/4 840D% 0.0000 0.0000 100.0000 FLOAT Immediately2100 PWM_FREQUENCY_M2 CR: / /D01, D05, EXP Pulse-width modulation frequency (not 810D) MSD ROT 2/4 840DHz 3200.0000 2000.0000 8000.0000 FLOAT PowerOn2102 MOTOR_CODE_M2 CR: / /D04, D05 Motor code number (not 810D) MSD ROT 2/4 840D- 0 0 65535 UNS. WORD PowerOn2103 MOTOR_NOMINAL_CURRENT_M2 CR: / /D05 Motor rated current (not 810D) MSD ROT 2/4 840DA 0.0000 0.0000 500.0000 FLOAT PowerOn2<strong>11</strong>7 MOTOR_INERTIA_M2 CR: / /D05 Motor moment of inertia (not 810D) MSD ROT 2/4 840Dkgm² 0.0010 0.0000 32.0000 FLOAT Immediately2<strong>11</strong>9 SERIES_INDUCTANCE_M2 CR: / /D05 Inductance of the series reactor (not 810D) MSD ROT 2/4 840DmH 0.0000 0.0000 65.0000 FLOAT PowerOn2120 CURRCTRL_GAIN_M2 CR: / /D01, EXP Current controller P gain (not 810D) MSD ROT 2/4 840DV/A 10.0000 0.0000 10000.0000 FLOAT Immediately2121 CURRCTRL_INTEGRATOR_TIME_M2 CR: / /D01, EXP Current controller integral action time (not 810D) MSD ROT 2/4 840Dus 2000.0000 0.0000 8000.0000 FLOAT Immediately2125 UF_MODE_RAMP_TIME_1_M2 CR: / /D04, EXP Ramp-up time 1 in V/f operation (not 810D) MSD ROT 2/4 840Ds 5.0000 0.0100 100.0000 FLOAT Immediately2126 UF_MODE_RAMP_TIME_2_M2 CR: / /D04, EXP Ramp-up time 2 in V/f operation (not 810D) MSD ROT 2/4 840Ds 5.0000 0.0100 100.0000 FLOAT Immediately2127 UF_VOLTAGE_AT_F0_M2 CR: / /D04, D05, EXP Voltage at f=0 in V/f operation (not 810D) MSD ROT 2/4 840DV 2.0000 0.0000 20.0000 FLOAT Immediately2129 POWER_FACTOR_COS_PHI_M2 CR: / /D05 Cos phi power factor (not 810D) MSD ROT 2/4 840D- 0.8000 0.0000 1.0000 FLOAT PowerOn© Siemens AG, <strong>2003</strong>. All rights reserved2-136 SINUMERIK 840D/840Di/810D SIMODRIVE 6<strong>11</strong> digital <strong>Lists</strong> (LIS) – <strong>11</strong>.03 <strong>Edition</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!