12.07.2015 Views

Lists 11/2003 Edition

Lists 11/2003 Edition

Lists 11/2003 Edition

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>11</strong>.03 2 Machine and Setting Data2.5 General machine data<strong>11</strong>322 CONTOURHANDWH_IMP_PER_LATCH [n]: 0 ... max. No. handwheels - 1 H1- Contour handwheel pulses per detent positionAdaptation factor to the hardware of the contour handwheel:Enter the number of pulses issued per detent position by the contour handwheel.Because of this normalization, a detent position of the contour handwheel correspondsto the pressing of a key with incremental jog processes.Inversion of signs causes inversion of direction evaluation.SW 6.3Display filters: N09POWER ONalways 1., 1., 1., 1., 1., 1. - - DOUBLE 2/7<strong>11</strong>324 HANDWH_VDI_REPRESENTATION OEM- Display of handwheel number in VDI Interface SW 6.3Display filters: N01POWER ONalways 0 0 1 DWORD 2/7<strong>11</strong>330 JOG_INCR_SIZE_TAB [n]: 0 ... 4 H1- Increment size for INC/handwheel SW 1Display filters: N09, EXPalways 1., 10., 100., 1000.,10000.POWER ON0.0 plus DOUBLE 2/7<strong>11</strong>340 ENC_HANDWHEEL_SEGMENT_NR H1, FBMA- 3rd handwheel: type of drive SW 4.1Display filters: N01, EXPPOWER ONalways 1 1 1 BYTE 0/0<strong>11</strong>342 ENC_HANDWHEEL_MODULE_NR H1, FBMA- 3rd handwheel: drive no./meas. circuit no. SW 4.1Display filters: N01POWER ONalways 0 0 10 BYTE 2/7<strong>11</strong>344 ENC_HANDWHEEL_INPUT_NR H1, FBMA- 3rd handwheel: Input to module/meas. circ. Board SW 4.1Display filters: N01POWER ONalways 1 1 2 BYTE 2/7<strong>11</strong>346 HANDWH_TRUE_DISTANCE H1, FBMA- Handwheel default path or velocity SW 4.1Display filters: N01POWER ONalways 1 0 3 BYTE 2/7<strong>11</strong>380 MONITOR_ADDRESS STZ- Test MD for setting NCK code or data for SINUMERIK Safety Integrated address of thememory location which is to be read/writtenAddress of memory location to be read/writtenSW 3.2Display filters: N06, EXP Attributes: NBUP IMMEDIATELYalways 0 - - DWORD 0/0<strong>11</strong>382 MONITOR_DISPLAY_INT STZ- INTEGER display of the addressed location SW 3.2Display filters: N06, EXP Attributes: NBUP IMMEDIATELYalways 0 - - DWORD 0/0<strong>11</strong>384 MONITOR_DISPLAY_REAL STZ- REAL display of the addressed location SW 3.2Display filters: N06, EXP Attributes: NBUP IMMEDIATELYalways 0.0 - - DOUBLE 0/0© Siemens AG, <strong>2003</strong>. All rights reservedSINUMERIK 840D/840Di/810D SIMODRIVE 6<strong>11</strong> digital <strong>Lists</strong> (LIS) – <strong>11</strong>.03 <strong>Edition</strong> 2-213

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!