12.07.2015 Views

Lists 11/2003 Edition

Lists 11/2003 Edition

Lists 11/2003 Edition

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

2 Machine and Setting Data <strong>11</strong>.032.6 Channel-specific machine data20124 TOOL_MANAGEMENT_TOOLHOLDER FBW- Toolholder number SW 3.2Display filters: C03Fct.: Toolmanagement0, 0, 0, 0, 0, 0, 0, 0, 0, 0,0, 0, ...POWER ON0 10 DWORD 2/720126 TOOL_CARRIER_RESET_VALUE W1- Active tool holder on RESET SW 4.1Display filters: C03always 0, 0, 0, 0, 0, 0, 0, 0, 0, 0,0, 0, ...RESET0.0 plus DWORD 2/720128 COLLECT_TOOL_CHANGE FBW- Tool change picked up in search run SW 4.3Display filters: C04Fct.: ToolmanagementIMMEDIATELY1 0 1 BOOLEAN 1/120130 CUTTING_EDGE_RESET_VALUE K2- Tool edge whose length compens. is selected during runup (reset/end of pp).SW 2Depends on MD 20<strong>11</strong>0 and 20<strong>11</strong>2.Display filters: C03always 0, 0, 0, 0, 0, 0, 0, 0, 0, 0,0, 0, ...RESET0 32000 DWORD 2/720132 SUMCORR_RESET_VALUE W1- Effective resulting offset on RESET SW 5Display filters: C03always 0, 0, 0, 0, 0, 0, 0, 0, 0, 0,0, 0, ...RESET0 6 DWORD 2/720140 TRAFO_RESET_VALUE K2- Transformation data block selected during runup (reset/pp end)SW 2Depends on MD 20<strong>11</strong>0 and 20<strong>11</strong>2.Display filters: C03RESETFct.:0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0 8 BYTE 2/7Transformations 0, 0, ...20150 GCODE_RESET_VALUES [n]: 0 ... Max. No. G codes - 1 K1, G2- Initial setting of G groupsSelection of some G groups[0] 1 = G0, 2 = G01 (Std)[5] 1 = G17 (Std), 2 = G18, 3 = G19[7] 1 = G500 (Std), 2 = G54, 3 = G 55, 4 = G56, 5 = G57[9] 1 = G60 (Std), 2 = G 64, 3 = G641[<strong>11</strong>] 1 = G601 (Std), 2 = G602, 3 = G603[12] 1 = G70, 2 = G71 (Std)[13] 1 = G90 (Std), 2 = G91[14] 1 = G93, 2 = G94 (Std), 3 = G95[20] 1 = BRISK (Std), 2 = SOFT[22] 1 = CDOF (Std), 2 = CDON[23] 1 = FFWOF (Std), 2 = FFWON[28] 1 = DIAMOF (Std), 2 = DIAMONFor more detailed information see Programming GuideG code definition depends on MD 20<strong>11</strong>0 and MD 20<strong>11</strong>2.SW 1Display filters: C03, C<strong>11</strong>always { 2, 0, 0, 1, 0, 1, 1, 1,...RESET0.0 plus BYTE 2/720152 GCODE_RESET_MODE [n]: 0 ... Max. No. G codes - 1 K2- Reset mode of G groups SW 4.4Display filters: C03RESETalways - 0 1 BYTE 2/7© Siemens AG, <strong>2003</strong>. All rights reserved2-238 SINUMERIK 840D/840Di/810D SIMODRIVE 6<strong>11</strong> digital <strong>Lists</strong> (LIS) – <strong>11</strong>.03 <strong>Edition</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!