12.07.2015 Views

Lists 11/2003 Edition

Lists 11/2003 Edition

Lists 11/2003 Edition

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>11</strong>.03 2 Machine and Setting Data2.3 Machine data for hydraulics module5500 NUM_SPEED_FILTERS [n] 0 ...7 Index of param. set CR: /FBHLA/D01 Number of velocity filters HLD 3/3 5.1 840D- 0 0 1 UNS. WORD immediately5501 SPEED_FILTER_TYPE [n] 0 ...7 Index of param. set CR: /FBHLA/D01 Type of velocity filter HLD 3/3 5.1 840DHEX 0 0 257 UNS. WORD immediately5502 SPEED_FILTER_1_TIME [n] 0 ...7 Index of param. set CR: /FBHLA/D01 PT1 time constant of velocity filter 1 HLD 3/3 5.1 840Dms 0.0 0.0 500.0 FLOAT immediately5506 SPEED_FILTER_1_FREQUENCY [n] 0 ...7 Index of param. set CR: /FBHLA/D01 PT 2 natural frequency of velocity filter 1 HLD 3/3 5.1 840DHz 2000.0 10.0 8000.0 FLOAT immediately5507 SPEED_FILTER_1_DAMPING [n] 0 ...7 Index of param. set CR: /FBHLA/D01 PT2 damping of velocity filter 1 HLD 3/3 5.1 840D- 0.7 0.2 1.0 FLOAT immediately5514 SPEED_FILTER_1_SUPPR_FREQ [n] 0 ...7 Index of param. set CR: /FBHLA/D01 BSF blocking frequency of velocity filter 1 HLD 3/3 5.1 840DHz 3500.0 10.0 7999.0 FLOAT immediately5515 SPEED_FILTER_1_BANDWIDTH [n] 0 ...7 Index of param. set CR: /FBHLA/D01 BSF bandwidth of velocity filter 1 HLD 3/3 5.1 840DHz 500.0 5.0 7999.0 FLOAT immediately5516 SPEED_FILTER_1_BW_NUMERATOR [n] 0 ...7 Index of param. set CR: /FBHLA/D01 Numerator bandwidth of velocity filter 1 HLD 3/3 5.1 840DHz 0.0 0.0 7999.0 FLOAT immediately5520 SPEED_FILTER_1_BS_FREQ [n] 0 ...7 Index of param. set CR: /FBHLA/D01 BSF natural frequency of velocity filter 1 HLD 3/3 5.1 840D% 100.0 1.0 141.0 FLOAT immediately5522 ACT_SPEED_FILTER_TIME CR: /FBHLA/D01 Time constant velocity actual value filter HLD 3/3 5.1 840DHEX 0 0 0 UNS. WORD PowerOn5530 CYLINDER_SAFETY_CONFIG CR: /FBHLA/D05, D02 Safety circuit HLD 3/3 5.1 840DHEX 4 0 3F UNS. WORD immediately5531 OUTPUT_ENABLE_DELAY CR: /FBHLA/D02 Manipulated variable blocking time HLD 3/3 5.1 840Dms 300 0 500 UNS. WORD immediately5532 POWER_ENABLE_DELAY CR: /FBHLA/D02 Power enable blocking time HLD 3/3 5.1 840Dms 100 0 300 UNS. WORD immediately5550 PRESSURE_SENS_A_REF CR: /FBHLA/D06 Reference value of pressure sensor A at 10 V HLD 3/3 5.1 840Dbar 200.0 50.0 6000.0 FLOAT immediately5551 PRESSURE_SENS_A_OFFS CR: /FBHLA/D06 Offset compensation for pressure sensor A HLD 3/3 5.1 840D- 0 -32760 32760 WORD immediately© Siemens AG, <strong>2003</strong>. All rights reservedSINUMERIK 840D/840Di/810D SIMODRIVE 6<strong>11</strong> digital <strong>Lists</strong> (LIS) – <strong>11</strong>.03 <strong>Edition</strong> 2-151

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!