12.07.2015 Views

Lists 11/2003 Edition

Lists 11/2003 Edition

Lists 11/2003 Edition

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>11</strong>.03 2 Machine and Setting Data2.5 General machine data10920 INDEX_AX_LENGTH_POS_TAB_2 T1- Number of positions for indexing axis table 2 SW 1Display filters: N09Fct.: Positioningaxes, Idx.RESET0 0 60 DWORD 2/710930 INDEX_AX_POS_TAB_2 [n]: 0 ... max. No. indexing pos. - 1 T1mm/inch, Indexing position table 2 SW 1degreesDisplay filters: N09RESETFct.: Positioningaxes, Idx.0., 0., 0., 0., 0., 0., 0., 0.,0., ...- - DOUBLE 2/7<strong>11</strong>100 AUXFU_MAXNUM_GROUP_ASSIGN H2- Number of auxiliary functions distr. amongst aux. fct. groups SW 1Display filters: N01, N02, N07POWER ONalways 1 1 255 DWORD 2/7<strong>11</strong><strong>11</strong>0 AUXFU_GROUP_SPEC [n]: 0 ... 63 H2HEX Auxiliary function group specificationBit 0 = 1: Output duration 1 OB1 passBit 1 = 1: Output duration 1 PLC basic cycleBit 2: -Bit 3 = 1: No output at the interfaceSW 1Bit 4: -Default setting:Bit 5 = 1: Output before movementGroup 1 = 81 HBit 6 = 1: Output during movementGroup 2 = 21 HBit 7 = 1: Output at end of blockGroup 3 - 15 = 41 HDisplay filters: N07always 0x81, 0x21, 0x41, 0x41,0x41, 0x41, ...POWER ON- - BYTE 2/7<strong>11</strong>120 LUD_EXTENDED_SCOPE PG- Activate function "program global user data (PUD)" SW 5Display filters: N01Fct.: NC memoryLUDPOWER ON0 0 1 BOOLEAN 2/7<strong>11</strong>140 GUD_AREA_SAVE_TAB [n]: 0 ... 8- Add. saving for GUD modules SW 6.1Display filters: N01IMMEDIATELYFct.: NC memory 0, 0, 0, 0, 0, 0, 0, 0, 0 - - DWORD 2/7GUD<strong>11</strong>200 INIT_MD IAF, IAD, IAHEX Standard machine data loaded at next Power On SW 1Display filters: N01, EXPPOWER ONalways 0 - - BYTE 2/7<strong>11</strong>210 UPLOAD_MD_CHANGES_ONLY IAD- MD backup of changed MD only SW 1Display filters: N01, N05IMMEDIATELYalways 0xFF - - BYTE 3/7<strong>11</strong>220 INI_FILE_MODE IAD- Error response to INI file errorsSW 30: Read-in aborted1 und 2: No abort, alarms outputDisplay filters: N01, N05RESETalways 1 0 2 BYTE 2/7© Siemens AG, <strong>2003</strong>. All rights reservedSINUMERIK 840D/840Di/810D SIMODRIVE 6<strong>11</strong> digital <strong>Lists</strong> (LIS) – <strong>11</strong>.03 <strong>Edition</strong> 2-2<strong>11</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!