12.07.2015 Views

Lists 11/2003 Edition

Lists 11/2003 Edition

Lists 11/2003 Edition

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>11</strong>.03 2 Machine- and Setting Data2.2 Drive machine data<strong>11</strong>50 FIELDCTRL_GAIN CR: DS1D01, EXPFlux controller P-gain MSD 2/4A/(Vs)HW:P2 400.000000 0.000000 100000.000000 FLOAT Immediately<strong>11</strong>50 FIELDCTRL_GAIN CR: /DS1 /D01, EXP Flux controller P-gain MSD ROT 2/4A/(Vs) 400.0000 0.0000 100000.0000 FLOAT Immediately<strong>11</strong>51 FIELDCTRL_INTEGRATOR_TIME CR: DS1D01, EXPFlux controller integral-action time MSD 2/4msHW:P2 10.000000 0.000000 500.000000 FLOAT Immediately<strong>11</strong>51 FIELDCTRL_INTEGRATOR_TIME CR: /DS1 /D01, EXP Flux controller integral-action time MSD ROT 2/4ms 10.0000 0.0000 500.0000 FLOAT Immediately<strong>11</strong>59 FLUX_MODEL_CORRECTION CR:D01, EXP, D04 Flow model correction MSD 2/4-HW:P2 1 0 1 UNS.WORD Immediately<strong>11</strong>60 FLUX_ACQUISITION_SPEED CR: DS1D01, EXPThreshold speed for flux sensing MSD 2/41/minHW:P2 1500.000000 200.000000 100000.000000 FLOAT Immediately<strong>11</strong>60 FLUX_AQUISITION_SPEED CR: / DS1/Threshold speed for flux sensing MSD 2/4 810D1/min 1500.0000 200.0000 50000.0000 FLOAT Immediately<strong>11</strong>60 FLUX_ACQUISITION_SPEED CR: /DS1 /D01, EXP Threshold speed for flux sensing MSD ROT 2/4 840D1/min 1500.0000 200.0000 100000.0000 FLOAT Immediately<strong>11</strong>61 FIXED_LINK_VOLTAGE CR: DS1D02Fixed DC link voltage MSD SLM FDD 2/4VHW:P2 0 0 700 UNS.WORD Immediately<strong>11</strong>61 FIXED_LINK_VOLTAGE CR: / DS1 /D02 Fixed DC link voltage FDD/MSD ROT/LIN 2/4V 0 0 700 UNS. WORD Immediately<strong>11</strong>70 POLE_PAIR_PITCH CR: , DL1D05Pole pair pitch SLM FDD 2/4mmHW:P2 72.000000 0.000000 1000.000000 FLOAT Power On<strong>11</strong>70 POLE_PAIR_PITCH CR: / DL1/D05 Pole pair pitch (not 810D) FDD LIN 2/4 840Dmm 72.0000 0.0000 1000.0000 FLOAT PowerOn<strong>11</strong>75 INVERTER_THERM_CURR_ASYN CR: DE1, DM1D05Power section ASYN limit current SLM FDD 2/4AHW:P2 200.000000 0.000000 500.000000 FLOAT Power On© Siemens AG, <strong>2003</strong>. All rights reservedSINUMERIK 840D/840Di/810D SIMODRIVE 6<strong>11</strong> digital <strong>Lists</strong> (LIS) – <strong>11</strong>.03 <strong>Edition</strong> 2-87

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!