12.07.2015 Views

Lists 11/2003 Edition

Lists 11/2003 Edition

Lists 11/2003 Edition

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>11</strong>.03 2 Machine- and Setting Data2.2 Drive machine data1230 ROT: TORQUE_LIMIT_1CR: DÜ1LIN: FORCE_LIMIT_1D02, EXPROT: 1st torque limitMSD SLM FDD 2/4%LIN: 1 st force thresholdHW:P2 100.000000 5.000000 900.000000 FLOAT Immediately1230 TORQUE_LIMIT_1 [n] 0 ...7 Index of param.-set CR: /DÜ1 /D02, EXP 1st torque limit FDD/MSD ROT 2/4% 100.0000 5.0000 900.0000 FLOAT Immediately1230 FORCE_LIMIT_1 [n] 0 ...7 Index of param.-set CR: / DL1/D02, EXP 1 st force threshold FDD LIN 2/4% 100.0000 5.0000 900.0000 FLOAT Immediately1231 ROT: TORQUE_LIMIT_2CR: DÜ1LIN: FORCE_LIMIT_2D02, EXPROT: 2nd torque limitMSD SLM FDD 2/4%LIN: 2nd force thresholdHW:P2 100.000000 5.000000 100.000000 FLOAT Immediately1231 TORQUE_LIMIT_2 CR: /DÜ1 /D02, EXP 2nd torque limit (not 810D) FDD/MSD ROT 2/4 840D% 100.0000 5.0000 100.0000 FLOAT Immediately1231 FORCE_LIMIT_2 CR: / DL1/D02, EXP 2nd force threshold (not 810D) FDD LIN 2/4 840D% 100.0000 5.0000 100.0000 FLOAT Immediately1232 ROT: TORQUE_LIMIT_SWITCH_SPEEDCR: DÜ1LIN: FORCE_LIMIT_SWITCH_SPEEDD02, EXPROT: Changeover speed from MD 1230 to MD 1231 MSD SLM FDD 2/4ROT: 1/minLIN: m/minLIN: Changeover speed from MD 1230 to MD 1231HW:P2 ROT: 6000.000000LIN: 120.0000000.000000 100000.000000 FLOAT Immediately1232 FORCE_LIMIT_SWITCH_SPEED CR: / DL1/D02, EXP Changeover speed from MD 1230 to MD 1231 (not 810D) FDD LIN 2/4 840Dm/min 120.0000 0.0000 100000.0000 FLOAT Immediately1232 TORQUE_LIMIT_SWITCH_SPEED CR: /DÜ1 /D02, EXP Changeover speed from MD 1230 to MD 1231 (not 810D) FDD/MSD ROT 2/4 840D1/min 6000.0000 0.0000 100000.0000 FLOAT Immediately1233 ROT: TORQUE_LIMIT_GENERATORCR: DÜ1LIN: LIMIT_GENERATORD02, EXPROT: Regenerative limitingMSD SLM FDD 2/4%LIN:HW:P2 100.000000 5.000000 100.000000 FLOAT Immediately1233 TORQUE_LIMIT_GENERATOR [n] 0 ...7 Index of param.-set CR: /DÜ1 /D02, EXP Regenerative limiting (not 810D) FDD/MSD ROT 2/4 840D% 100.0000 5.0000 100.0000 FLOAT Immediately1233 LIMIT_GENERATOR [n] 0 ...7 Index of param.-set CR: / DL1/D02, EXP Generator force limiting (not 810D) FDD LIN 2/4 840D% 100.0000 5.0000 100.0000 FLOAT Immediately© Siemens AG, <strong>2003</strong>. All rights reservedSINUMERIK 840D/840Di/810D SIMODRIVE 6<strong>11</strong> digital <strong>Lists</strong> (LIS) – <strong>11</strong>.03 <strong>Edition</strong> 2-95

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!