<strong>11</strong>.03 2 Machine- and Setting Data2.2 Drive machine data1624 PROG_SIGNAL_HYSTERESIS CR: / DD1 /D03 Hysteresis, variable message function (not 810D) FDD/MSD ROT/LIN 2/4 840D- 0 0 16777215 UNS. DWORD Immediately1625 PROG_SIGNAL_ON_DELAY CR: DD1D03Pickup delay time, variable message function MSD SLM FDD 2/4msHW:P2 0 0 10000 UNS.WORD Immediately1625 PROG_SIGNAL_ON_DELAY CR: / DD1 /D03 Pickup delay time, variable message function (not 810D) FDD/MSD ROT/LIN 2/4 840Dms 0 0 10000 UNS. WORD Immediately1626 PROG_SIGNAL_OFF_DELAY CR: DD1D03Dropout delay, variable message function MSD SLM FDD 2/4msHW:P2 0 0 10000 UNS.WORD Immediately1626 PROG_SIGNAL_OFF_DELAY CR: / DD1 /D03 Dropout delay, variable message function (not 810D) FDD/MSD ROT/LIN 2/4 840Dms 0 0 10000 UNS. WORD Immediately1630 LINK_VOLTAGE_MON_THRESHOLD CR: DÜ1EXPResponse threshold, only DC link monitoring MSD SLM FDD 2/4VHW:P2 550 0 680 UNS.WORD Immediately1630 LINK_VOLTAGE_MON_THRESHOLD CR: / DÜ1 /EXP Response threshold, only DC link monitoring (not 810D) FDD/MSD ROT/LIN 2/4 840DV 550 0 680 UNS. WORD Immediately1631 LINK_VOLTAGE_GEN_ON CR: DE1EXPResponse voltage of generator axis MSD SLM FDD 2/4VHW:P2 450 280 650 UNS.WORD Immediately1631 LINK_VOLTAGE_GEN_ON CR: / DE1 /EXP Response voltage of generator axis (not 810D) FDD/MSD ROT/LIN 2/4 840DV 450 280 650 UNS. WORD Immediately1632 LINK_VOLTAGE_GEN_HYST CR: DE1EXPVoltage range for generator control MSD SLM FDD 2/4VHW:P2 30 0 300 UNS.WORD Immediately1632 LINK_VOLTAGE_GEN_HYST CR: / DE1 /EXP Voltage range for generator control (not 810D) FDD/MSD ROT/LIN 2/4 840DV 30 0 300 UNS. WORD Immediately1633 LINK_VOLTAGE_GEN_OFF CR: DE1EXPShutdown threshold of generator operation MSD SLM FDD 2/4VHW:P2 510 0 660 UNS.WORD Immediately1633 LINK_VOLTAGE_GEN_OFF CR: / DE1 /EXP Shutdown threshold of generator operation (not 810D) FDD/MSD ROT/LIN 2/4 840DV 510 0 660 UNS. WORD Immediately1634 LINK_VOLTAGE_RETRACT CR: DE1EXPResponse threshold emergency retraction MSD SLM FDD 2/4VHW:P2 400 0 660 UNS.WORD Immediately© Siemens AG, <strong>2003</strong>. All rights reservedSINUMERIK 840D/840Di/810D SIMODRIVE 6<strong>11</strong> digital <strong>Lists</strong> (LIS) – <strong>11</strong>.03 <strong>Edition</strong> 2-123

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!