13.07.2015 Views

Barrel Heaters - Hasmak.com.tr

Barrel Heaters - Hasmak.com.tr

Barrel Heaters - Hasmak.com.tr

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Power Con<strong>tr</strong>ollersDIN-A-MITE FamilyReduce Wear On Thermal SystemWith optional variable time baseswitching, the DIN-A-MITEautomatically adjusts output cycletime to meet system demands.The benefits of this option are:• Heater output equal to loaddemand• Minimized temperature over- andundershootTerminal System Helps PreventWiring FailuresA proven high-current copperterminal design ensures optimumelec<strong>tr</strong>ical connection to reduce heatbuild-up. This helps avoidconnection failures and ensuresoverall wiring reliability. To furtherreduce “hot spots,” we’ve eliminatedall unnecessary wires and fastenerswhich could possibly loosen, heat upand break down.Compact Solid State PowerCon<strong>tr</strong>oller Delivers BigPerformance in a Small PackageWatlow’s DIN-A-MITE Style A, B, Cand D power con<strong>tr</strong>ollers provide alow-cost, highly <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>pact andversatile solid state power con<strong>tr</strong>ol.What’s more, no need to worry aboutmercury; all DIN-A-MITEs aremercury free and fit the samefootprint as a <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>parably ratedMDR. Each feature sub-panelmounting, while Styles A, B and Calso have DIN-rail mountingcapability.Style A CapabilitiesStyle A capabilities include singlephaseburst fire switching up to 25amps at 600VÅ(ac) (see rating curve).Variable time base, 4-20mAÎ(dc)process con<strong>tr</strong>ol or VÅ(ac)/ VÎ(dc)input contactor versions areavailable. All configurations are codenumber dependent and factoryselectable, 50/60Hz independent.Style B CapabilitiesStyle B capabilities include 1-phaseand 3-phase burst fire up to 40 and33 amps, respectively, at 600VÅ(ac)(see rating curve).Variable time base, 4-20mAÎ(dc)process con<strong>tr</strong>ol or VÅ(ac)/VÎ(dc)input contactor versions areavailable. All configurations are codenumber dependent and factoryselectable, 50/60Hz independent.Style C CapabilitiesStyle C capabilities include 1-phaseand 3-phase, 2-leg, and 3-phase,3-leg burst fire, as well as 1-phase,phase-angle fire. Burst fire operationfrom 120 to 600VÅ(ac), phase-angleoperation from 120 to 600VÅ(ac).Current switching capabilities rangefrom 30 to 80 amps depending onthe model ordered (see output ratingcurve).Input options include variable timebase, 4-20mAÎ(dc) process con<strong>tr</strong>ol,linear voltage con<strong>tr</strong>ol, manual con<strong>tr</strong>olor VÅ(ac)/VÎ(dc) contactor input.All configurations are code numberdependent and factory selectable.All models are 50/60Hz independent.Style D CapabilitiesStyle D capabilities include 1-phaseswitching up to 100 amps at600VÅ(ac) and 30°C (86°F) (seerating curve). Limited 3-phaseoperation is possible by ganging twoand/or three Style D DIN-A-MITEcontactor inputs together.Style D features on-boardsemiconductor fuses (accessiblefrom the front). Application is furtherenhanced with optional current<strong>tr</strong>ansformer option for external loadcurrent monitoring and “shorted SCRdetector” on some models.Variable time base, 4-20mAÎ(dc)process con<strong>tr</strong>ol or VÅ(ac)/ VÎ(dc)input contactor options are available.All configurations are code numberdependent and factory selectable,50/60Hz independent.The standard sub-panel mountingfootprint is equal to that of an indus<strong>tr</strong>ystandard mercury displacement relay.DIN-A-MITE Style A, B, C and DFeatures• Faster switching with solid state<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>ponents. Better con<strong>tr</strong>ol savesenergy and extends heater life.• Back-to-back SCR design forincreased durability.• Three-year warranty assuresCon<strong>tr</strong>ol Confidence ® .Style B and C Features• 1- and 3-phase power permitsuse in a variety of applications.• Shorted output detector(optional) notifies a shorted SCRcondition.Style C Features• Open heater detector (optional)notifies when a partial or totallyopen heater occurs.Style D Features• On-board semiconductor fusingprovides quick access with noex<strong>tr</strong>a mounting necessary.• Optional load current monitordetects changes in load current.Agency Approvals• UL ® 508 Listed, File #E73741• C-UL ® approved• CE approved with proper line filter• DIN-A-MITE Style C thru-wallmount is also UL ® 50 andUL ® 1604 approved.• CE and EN 61326 Indus<strong>tr</strong>ialImmunity Class A emissions withfilter. EN 50178 safety directive184

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!