13.07.2015 Views

Barrel Heaters - Hasmak.com.tr

Barrel Heaters - Hasmak.com.tr

Barrel Heaters - Hasmak.com.tr

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Resources and InformationReference DataW A T L O WReference DataPower Con<strong>tr</strong>ollersFour Basic TypesContinued4a. DIN-A-MITE ® SCRPower Con<strong>tr</strong>ollerThe DIN-A-MITE ® Power con<strong>tr</strong>oller<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>bines SCR con<strong>tr</strong>ol, heat sink,wiring and a touch safe exterior in one<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>plete package. The DIN-A-MITEcon<strong>tr</strong>oller configured with variabletime base switches as fast as three acwave cycles (less than 0.1 seconds).Set point deviation is virtuallyeliminated, providing the finestcon<strong>tr</strong>ol, lowest power consumptionand longest heater element life.Power Output Types:One poleTwo poleThree poleSingle-phase loadsThree-phase ungrounded loads onlyTwo pole multizone for two independent single-phase loadsThree-phase grounded Y loads, inside deltaThree pole multizone for three independent single-phase loadsType of Con<strong>tr</strong>ol:Contactor (C input) is on-off; on whenthe <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mand signal is present, offwhen the <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mand signal is absent.The temperature con<strong>tr</strong>oller does theproportioning. It is available with ac ordc <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mand signal.Variable time base (V input) is looppowered and requires an analog input(4 to 20 mA only) to set the power.The DIN-A-MITE con<strong>tr</strong>oller does theproportioning. At 50 percent powerthe load is on for 3 cycles and off forthree cycles. At 25 percent power it ison three cycles and off nine. Cannotuse voltage or pot input.Phase-angle (P input) con<strong>tr</strong>ol isinfinitely variable from full off to full on.It varies the turn-on time inside thesine wave. This provides a variablevoltage and current con<strong>tr</strong>ol. Thisoption includes soft start, line voltage<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>pensation and will work with a mAsignal, a linear voltage signal or a potinput. It will also con<strong>tr</strong>ol the primary ofa step down <strong>tr</strong>ansformer. (This issingle-phase only.)The shorted SCR alarm option uses acurrent <strong>tr</strong>ansformer to sense loadcurrent and a <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>parator to look atload current and <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mand signal. Ifthere is <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mand signal and loadcurrent, everything is OK. If there isload current but no <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mand signal,the alarm will activate. The alarmoutput is a 0.25 amp <strong>tr</strong>iac that can beused to turn on a relay. The alarm willnot work on the phase angle optionand also will not work on a three poleDIN-A-MITE with an ungrounded load.407

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!