13.07.2015 Views

Barrel Heaters - Hasmak.com.tr

Barrel Heaters - Hasmak.com.tr

Barrel Heaters - Hasmak.com.tr

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Power Con<strong>tr</strong>ollersStyle COrdering InformationTo order, <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>plete the code number on the right with the information below:DIN-A-MITED C _ _ - _ _ _ _ - _ _ _ _Current Rating TablePhase Cooling Currentat 50˚C(122˚F)1 0 55A1 T 60A1 (1,2,3) 75A2, 8 0 40A2, 8 T 45A2, 8 (1,2,3) 65A3, 9 0 30A3, 9 T 35A3, 9 (1,2,3) 55AAvailabilityAll <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>binations available in threeworking days or less.CE approved product. Must useCE filter listed on page 287 forconducted emission.Style C = Zero cross solid state power con<strong>tr</strong>oller in natural andforced air cooled versionsPhase1 = 1-phase, 1 con<strong>tr</strong>olled leg2 = 3-phase, 2 con<strong>tr</strong>olled legs3 = 3-phase, 3 con<strong>tr</strong>olled legs (use with four wire wye)8 = 2 independent zones (Input Type C, K)9 = 3 independent zones (Input Type C, K)Cooling and Current rating Per Leg (see table on left)0 = Natural convection standard DIN-rail or panel heatsink1 = Fan cooled 120VÅ(ac) standard DIN-rail or panel heatsink2 = Fan cooled 240VÅ(ac) standard DIN-rail or panel heatsink3 = Fan cooled 24VÎ(dc) standard DIN-rail or panel heatsinkT = Natural convection through wall or cabinet heatsink (NEMA 4X)Line and Load Voltage02 = 24 to 48VÅ(ac) (Con<strong>tr</strong>ol C, F, K)24 = 100 to 240VÅ(ac) (Con<strong>tr</strong>ol C, F, K)60 = 277 to 600VÅ(ac) (Con<strong>tr</strong>ol C, F, K)Input Con<strong>tr</strong>ol SignalC0 = 4.5 to 32VÎ(dc) contactorF0 = 4 to 20mAÎ(dc) proportionalK1 = 22 to 26VÅ(ac) contactorK2 = 100 to 120VÅ(ac) contactorK3 = 200 to 240VÅ(ac) contactorAlarm0 = No alarmS = Shorted SCR alarmLanguage0 = English1 = German2 = Spanish3 = FrenchCustom Part Numbers00 = Standard partXX = Any letter or number, custom options, labeling, etc.Re<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mended Semiconductor Fuses and Fuse KitsSee page 288 for listings and part numbers.Note: Allow one fuse and one holder per leg fused. Example, a 3-phase,2-leg DIN-A-MITE requires two fuses and two holders.190

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!