13.07.2015 Views

Barrel Heaters - Hasmak.com.tr

Barrel Heaters - Hasmak.com.tr

Barrel Heaters - Hasmak.com.tr

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Power Con<strong>tr</strong>ollersProblem SolversWatlow Solutions To CommonPower Con<strong>tr</strong>oller ProblemsPower con<strong>tr</strong>oller replacement intervalscan be lengthened or problemseliminated by using the optimum powercon<strong>tr</strong>oller for the application. Check thelist below to see if Watlow powercon<strong>tr</strong>ollers can improve your process.ProblemPremature heater failureExcessive contactor failureWasted powerUnsafe panel wiringEnvironmental concerns aboutMDRsExcessive EMI causingproblems in con<strong>tr</strong>ol circuitsPower Con<strong>tr</strong>ol Solution• Stabilize heater element temperature and reduce thermal s<strong>tr</strong>ess by usinga solid state power con<strong>tr</strong>ol along with a PID temperature con<strong>tr</strong>oller toreduce the temperature con<strong>tr</strong>ol cycle time• Replace elec<strong>tr</strong>omechanical contactors with solid state relays.Use E-SAFE ® RELAY for long cycle times, solid state relays for short cycletimes and PID con<strong>tr</strong>ol• Reduce temperature overshoot and power consumption by smoothing outtemperature/heating cycles with solid state power con<strong>tr</strong>ol and PIDtemperature con<strong>tr</strong>ol• The DIN-A-MITE ® power con<strong>tr</strong>ollers, when properly wired are totally safefrom finger and palm elec<strong>tr</strong>ical shock• Replace with solid state power con<strong>tr</strong>oller or E-SAFE RELAY.The DIN-A-MITE has the same footprint as many MDRs• Correct wire routing for minimum EMI pick-up; change fromelec<strong>tr</strong>omechanical and mercury relays, and/or phase-angle fired solidstate devices to zero cross (burst firing) solid state power con<strong>tr</strong>olCase HistoryE-SAFE ® RELAY DeliversLower Costs and IncreasedProductivityProblem:A plastics molder utilizedmechanical relays (contactors) inthe power con<strong>tr</strong>ol circuits of their100-ton injection molding machine.The relays had to be replaced every250,000 cycles and each changerequired a two hour shutdown of theproduction line. The manufactureralso had to dispose of theenvironmentally hazardous mercuryfrom the failed contactors.202Solution:To avoid these frequent shutdowns,Watlow E-SAFE RELAYs wereinstalled. E-SAFE RELAYs werepriced lower than the contactors,while also offering longer life.The E-SAFE RELAY provided highperformance in a non-mercuryoffering and eliminated the toxicwaste from failed mercurycontactors.After millions of cycles of operation,the customer informed Watlow thatthe E-SAFE RELAYs were stillperforming like new and had savedthem thousands of dollars inreplacement costs. In addition, hadthey continued to use the contactors,they would have experienced 24production shutdowns and 48 hoursof lost production time.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!