13.07.2015 Views

Barrel Heaters - Hasmak.com.tr

Barrel Heaters - Hasmak.com.tr

Barrel Heaters - Hasmak.com.tr

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TemperatureCon<strong>tr</strong>ollersCPC400Ordering InformationTo order, <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>plete the model number on the right with the information below.4 0 - 1Number of Loops4 = 4 loops8 = 8 loopsCon<strong>tr</strong>oller Type1 = Standard EPROMTerminal Board0 = No terminal board accessory1 = 18-pin terminal block mounted on unit (no SCSI cable required)2 = 50-pin terminal board (includes 3 foot SCSI cable)Power Supply0 = No power supply2 = 120/240VÅ(ac), 50/60Hz power supply adapter(5VÎ[dc] @ 4A, 15VÎ[dc] @ 1.2A) (CE approved)SCSI Cables (For use with 50-pin terminal board)0 = No special SCSI cable (3 foot cable included with 50-pin terminal block)1 = 6 foot SCSI cable2 = 3 foot right angle SCSI cable3 = 6 foot right angle SCSI cableSerial Communication Cables(For <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>munications with <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>puter)0 = No serial <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>munication cable1 = 10 foot serial <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>munication cable (DB-9 female/bare wire)2 = 25 foot serial <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>munication cable (DB-9 female/bare wire)3 = 50 foot serial <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>munication cable (DB-9 female/bare wire)Serial Communication Jumper Settings0 = EIA/TIA-2321 = EIA/TIA-4852 = EIA/TIA-485 terminatedSpecial Inputs(Standard unit is configured for thermocouples and -10 to 60mV linear inputs.For other sensors, order special inputs.)0 = Thermocouples and -10 to 60mV inputs onlyX = Number of current, voltage or RTD inputsSpecial InputsSpecify an input type for each channel or block of channels that needs factory installed resistors.Include a descriptor in the con<strong>tr</strong>oller part description in the form specified below for each specialinput type. Make sure the number of special inputs specified is equal to the number of specialinputs in the con<strong>tr</strong>oller part number.C P C S I - -Special Input Type(Not required for thermocouple sensor inputs)23 = RTD43 = 0-10mAÎ(dc)44 = 0-20mAÎ(dc)/4-20mAÎ(dc)50 = 0-100mVÎ(dc)52 = 0-500mVÎ(dc)53 = 0-1VÎ(dc)55 = 0-5VÎ(dc)56 = 0-10VÎ(dc)57 = 0-12VÎ(dc)Start ChannelXX = Channel Number XXEnd ChannelXX = Channel Number XXAvailabilityUp to 4 weeks, depending on <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>plexity and order release quantity. Consult factory for details.252

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!