13.07.2015 Views

Barrel Heaters - Hasmak.com.tr

Barrel Heaters - Hasmak.com.tr

Barrel Heaters - Hasmak.com.tr

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TemperatureCon<strong>tr</strong>ollers16-, 32-LoopMLS300Analog Input Module(AIM332 shown)165 mm L(6.5 in.)Compact Input Module(CIM332 shown)191 mm(7.50 in.)AvailabilityUp to four weeks depending on<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>plexity and order releasequantity. Consult factory for details.25670 mm(2.75 in.)146 mm H(5.75 in.)W127 mm(5.0 in.)95 mm(3.75 in.)Ordering InformationTo order, <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>plete the code number to the right with the information below:3 _ _ - _ _ _ _ _ _ _ _ _Input Module16 = 16 channel analog input module (AIM316)32 = 32 channel analog input module (AIM332)C1 = 16 channel <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>pact input module (CIM316)C2 = 32 channel <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>pact input module (CIM332)Processor Module (MLS300-PM)0 = Input module only (No MLS300-PM)1 = MLS300-PM with standard firmware2 = MLS300-PM with ex<strong>tr</strong>uder firmware3 = MLS300-PM with enhanced features firmware4 = MLS300-PM with ramp and soak firmwareTerminal Block0 = No terminal block accessory1 = 50-pin terminal block, includes 3 foot SCSI cablePower Supply0 = None2 = 120/240VÅ(ac) 50/60Hz power supply adapter[5VÎ(dc) @ 4A, 15VÎ(dc) @ 1.2A] CE approvedSCSI Cables (For use with 50-pin terminal board)0 = No special SCSI cable (3 foot cable is included with 50-pin terminal board)1 = 6 foot SCSI cable2 = 3 foot right angle SCSI cable3 = 6 foot right angle SCSI cableSerial Communication Cables (For <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>munications with <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>puter)0 = No serial <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>munications cable1 = 10 foot EIA/TIA-232 <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>m. cable, DB-9 female/RJ12 phone plug2 = 25 foot EIA/TIA-232 <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>m. cable, DB-9 female/RJ12 phone plug3 = 50 foot EIA/TIA-232 <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>m. cable, DB-9 female/RJ12 phone plug7 = EIA/TIA-485 terminal block with 2 foot cable8 = EIA/TIA-485 terminal block with 4 foot cableModule Interconnect Cables0 = No special cable (4 foot cable <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>es with input module)1 = 10 foot cable, RJ45 connector/RJ45 connector2 = 25 foot cable, RJ45 connector/RJ45 connectorSerial Communication Jumper0 = EIA/TIA-2321 = EIA/TIA-4852 = EIA/TIA-485 terminatedSpecial Inputs(Standard unit is configured for thermocouples and -10 to 60 mV linear inputs.For other sensors, order special inputs)00 = Thermocouples and -10 to 60 mV inputs onlyXX = Number of current, voltage, or RTD inputs. Include leading zero as neededM L S 3 0 0 S I _ _ - _ _ - _ _Special Input Type20 = RTD 1: 0.1° Platinum, -100 to 275°C (-148 to 527°F)21 = RTD 2: 1° Platinum, -120 to 840°C (-184 to 1544°F)43 = 0-10mAÎ(dc)44 = 0-20mAÎ(dc)/4-20mAÎ(dc)50 = 0-100mVÎ(dc)52 = 0-500mVÎ(dc)53 = 0-1VÎ(dc)55 = 0-5VÎ(dc)56 = 0-10VÎ(dc)57 = 0-12VÎ(dc)Start ChannelXX = Channel number XXEnd ChannelXX = Channel number XX

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!