(H-a) = 4.25 m<br />

Figure 5: Return air tunnel geometry.<br />

5.0 RECOMMENDATIONS<br />

CLOSURE WALL CAPACITY<br />

Calculations based on average stresses over <strong>the</strong> length of <strong>the</strong> closure wall (with conservative assumptions) and<br />

fur<strong>the</strong>r checking with boundary element stress analyses, suggests that a fac<strong>to</strong>red shear strength capable of<br />

resisting a pressure of 10.2 MPa is achievable. Using a load fac<strong>to</strong>r of 1.6 (ACI 318M), <strong>the</strong> allowable gas<br />

pressure acting on <strong>the</strong> face of <strong>the</strong> closure wall is 6.3 MPa.<br />

This allowable pressure is based on <strong>the</strong> ‘no dilation’ mechanism (and, <strong>the</strong>refore no normal stress on <strong>the</strong><br />

interface), which is a reasonable lower bound strength for <strong>the</strong> closure wall. Should <strong>the</strong> loaded end of <strong>the</strong> closure<br />

wall slip due <strong>to</strong> excess shear stress; or due <strong>to</strong> expansion of <strong>the</strong> walls (as a result of <strong>the</strong> gas pressure); or even<br />

due <strong>to</strong> some pressure penetrating <strong>the</strong> interface near <strong>the</strong> end of <strong>the</strong> closure wall, compression and ‘bulging’ of <strong>the</strong><br />

closure wall would occur and generate a normal stress across <strong>the</strong> interface resulting in increased shear capacity.<br />

6.0 REFERENCES<br />

q = 69.416<br />

[1] L&ILW DGR – Geotechnical Interpretative Report, Golder Document No. 1011170042-REP-G2050-<br />

0001-00, March 2011<br />

August 27, 2012<br />

Report No. 1011170042-TM-G2170-0001-00 8<br />

a = 0.75 m<br />

W = 4.8 m<br />

H = 5.00 m