June 15,1998<br />

Field QC Samples, May 1998, Holden Mine<br />

After data qualification, the following metals were detected in the filter blanks as noted below:<br />

I Analvte Detection Limit Filter Blank #I Filter Blank #2<br />

Aluminum<br />

Barium<br />

Cadmium<br />

Manganese<br />

4 U<br />

0.04 ug/L<br />

0.04 UQIL<br />

0.04 ugk<br />

Not Deteded<br />

0.1 1 ug/L<br />

Not Deteded<br />

Not Deteded<br />

The two filter blanks were collected from the same filter lot. Due to the proximity of the results to<br />

the detection limit, the data does not clearly lndlcate an additive effect from the filters. In additlon, the<br />

detection-limit reported for aluminum is below the project requirements. The filters were considered<br />

acceptable for use during the May 1998 sampling event.<br />

I 3. Laboratory Control Sample - Not Applicable<br />

4. Laboratory Duplicate - Not Applicable<br />

. ,.. A l'aboratory duplicate is not required fck fieldqualdy control samples.<br />

I 5. Field Duplicate - Not Applicable<br />

6; Matrix Spike - Not Applicable<br />

. A inatrix spike is not required for field quality control samples.<br />

7. Detedion Limits - Acceptable<br />

8. Type of Review - Summary<br />

9. Overall Assessment of Data<br />

The usefulness of the data is based on EPA guidance documents listed above. Upon<br />

conslderatlon of the information presented above, the data are acceptable except where flagged with<br />

data qualifiers that modify the usefulness of the individual values<br />

Data Qualifiers<br />

U The analyte was analyzed for, but was not detected above the reported sample quantitation limit.<br />

J The analyte was positively identified; the associated numerical value is the approximate<br />

concentration of the analyte in the sample.<br />

UJ The analyte was not detected above the reported sample quantitation limit. However, the<br />

reported quantitation limit is approximate and may or may not represent the actual limit of<br />

quantitation necessary to accurately and precisely measure the analyte in the sample.<br />

R The sample results are rejected due to serious deficiencies in the ability to analyze the sample<br />

and meet quality control criteria. The presence or absence of the analyte cannot be verified.