Rosa Environmental & Geotechnical Laboratory, LLC<br />

Client: <strong>Dames</strong> & <strong>Moore</strong> REGL Project No.: 1000-1 21<br />

Client Project No.: 17693-005-01 9 Sample Batch No.: 1000-1 21-01<br />

Case Narrative<br />

400 Ninth Avenue N., Suite B<br />

Seattle, WA 98 109-5 187<br />

(206) 287-9 122<br />

1 The samples were received on October 19, 1998 and were in good condition.<br />

2. There were eighteen samples for PSEP grain size analysis. A triplicate was run on one<br />

sample.<br />

3. The samples were set-up for testing on October 21, 1998. The analysis was complete on<br />

October 27, 1998.<br />

4. PSEP methodology requires that there be between 5 and 25 g in the pipehe portion of the<br />

analysis. The method also requires that all weights be measured to the nearest 0.1 mg, which<br />

limits the size of the test portion to 205 g. In most cases, a test.portion that would meet the 5<br />

g limit is too large to weigh on the analytical balance. Many of the samples reported in this<br />

set'contained less than the 5 g limit. The analysis was run anyway and the data has been<br />

flagged (noted in italicslshading in the summary table). Because of the lack of fines in these<br />

samples, the amount retained in many of the individual size fractions was less than the<br />

detection limit. These samples have been reported as 'NA" in the table, and were shown in<br />

the plots as "0.0."<br />

5. Each. bench sheet lists a simple sieve bydeve visual observation of the amount of organic<br />

material contained in each sample. All but one sample have similar organic characteristics;<br />

generally, organic material accounts for all weights from the #120 sieve and larger. The<br />

exception is sample LUC-SED-101598-1-1 which contained only 2 pine needles in the #I8<br />

all shiny flecks (mica?). -<br />