10 Programming Chart<br />

Programming Chart<br />

[System]<br />

[Methods]<br />

[Series]<br />

[Start/Stop]<br />

[Priority]<br />

[Hold/Cont.]<br />

Ready screen<br />

<br />

Perform<br />

standard<br />

wash<br />

Maintenance<br />

functions.<br />

System Settings<br />

1<br />

Copy<br />

methods<br />

Erase<br />

methods<br />

Midas<br />

logbook<br />

Serial<br />

communication<br />

protocol<br />

Control<br />

column oven<br />

temperature<br />

Control<br />

sample tray<br />

cooling<br />

<br />

Loop volume<br />

Needle volume<br />

Syringe volume<br />

Syringe speed<br />

Skip missing vials<br />

Air segment<br />

Headspace pressure<br />

Use calibration<br />

vials<br />

Method programming<br />

Tray type Inject marker pulse length<br />

Input edge next injection<br />

Freeze input active<br />

Reset outputs after last<br />

Series<br />

Service<br />

mode<br />

Device identifier Select Prep mode 2<br />

<br />

Injection type:<br />

<br />

Flush volume<br />

No injections/vial<br />

Analysis time<br />

Flush volume<br />

No injections/vial<br />

Injection volume<br />

Analysis time<br />

Method number<br />

First sample vial<br />

Last sample vial<br />

Use calibration vials 3<br />

First calibration vial<br />

Last calibration vial<br />

Vials between calibration<br />

First destination vial 4<br />

First Series<br />

Last Series<br />

<br />

Sample vial<br />

Hold the analysis time of the Midas<br />

Fig. 1 Programming chart<br />

No injections/vial<br />

Injection volume<br />

Analysis time<br />

Wash volume Timed events program: Mix program:<br />

Wash between:<br />

- Series<br />

- Vials<br />

- Series<br />

- 4 x AUX-1<br />

- 4 x AUX-2<br />

- INITIAL OVEN SETPOINT<br />

- 2 x OVEN SETPOINT<br />

- END TIME<br />

1. Available when the optional tray cooling is installed.<br />

2. When selecting the Prep mode, some system settings are no longer programmable, but set to a fixed value.<br />

3. Depends on the System Settings.<br />

4. In case Destination vials are used in the mix of the method.<br />

- Add<br />

- Mix<br />

- Wait