Operation 35<br />

General System Settings<br />

Press :<br />

GENERAL<br />

SYSTEM<br />

SETTINGS<br />

Volume of<br />

installed<br />

loop:<br />

Volume of<br />

tubing<br />

needle -><br />

valve:<br />

Syringe<br />

volume:<br />

Syringe<br />

speed:<br />

Skip missing<br />

vials:<br />

Range<br />

Comment<br />

0-5000 µl The volume of the installed loop.<br />

The AS <strong>3900</strong> uses this value for<br />

calculations of injection volumes.<br />

0-999 µl The volume of the tubing and needle<br />

connected to the injection valve.<br />

The AS <strong>3900</strong> uses this value for<br />

calculations of flush and transport<br />

volumes.<br />

The volume of the installed syringe.<br />

<br />

<br />

<br />

<br />

<br />

<br />

Air segment: <br />

<br />

Headspace<br />

pressure:<br />

<br />

<br />

The aspirating and dispensing<br />

speed are programmable in three<br />

steps:<br />

NORMAL for samples with a<br />

viscosity almost equal to the<br />

viscosity of water.<br />

LOW for samples with a higher<br />

viscosity and HIGH for samples with<br />

a lower viscosity compared to water.<br />

(See Table 4: Syringe speed.).<br />

Define if the AS <strong>3900</strong> has to stop if a<br />

vial is not found or continue with the<br />

next programmed vial.<br />

Program to stop the AS <strong>3900</strong><br />

in case a vial is not found.<br />

Inject a sample with or without an air<br />

segment between the sample and<br />

the wash solvent. If the air segment<br />

is ON (YES) the AS <strong>3900</strong> will draw<br />

an air segment of 5 µl before the<br />

flush volume prior to an injection.<br />

The air segment will not be injected<br />

in the analytical system.<br />

In case of µl pick-up the sample will<br />

be preceded by an air segment,<br />

which will be injected in the<br />

analytical system. (see page 18)<br />

The AS <strong>3900</strong> normally uses<br />

headspace pressure in combination<br />

with the syringe to transport sample<br />

in to the loop. If, for some reason, no<br />

headspace pressure is allowed, it<br />

can be switched OFF (NO). The<br />

compressor will always be used in<br />

the wash position of the AS <strong>3900</strong>.<br />

The accuracy and reproducibility of<br />

the AS <strong>3900</strong> can decrease when NO<br />

headspace pressure is used.