12 About AS <strong>3900</strong><br />

Side-port needle: a good point!<br />

The strong side-port needle combines the optimum point style for piercing<br />

with a minimum risk of blockage by septum particles. For small sample<br />

volumes, a spring-loaded needle is available for maximum sample<br />

aspiration independent of variations in vial dimensions.<br />

Column oven for consistent results.<br />

A column oven is an integral part of AS <strong>3900</strong>, because constant column<br />

temperature is important for long term stability of a chromatographic<br />

separation and may be required by GLP directives.<br />

Integrated sample cooling option.<br />

Thermo-electric sample cooling is available as a fully integrated option.<br />

No external device is required and the efficient cooling concept does not<br />

restrict access to the sample tray during operation.<br />

Reagent addition made simple.<br />

Internal Standard addition, sample dilution or derivatization can be<br />

programmed in a very simple manner. A single-stage derivatization of a<br />

sample in a separate (destination) vial requires no more than 4 program<br />

lines. Multi-reagent addition is also possible: two large volume reagent<br />

vials are available on the sample tray.<br />

PC-based control.<br />

For communication with external computers, a serial interface and<br />

<strong>Smartline</strong> communication protocol are standard. A Microsoft® Windows<br />

based software package for AS <strong>3900</strong> control from a PC greatly improves<br />

operation and programming convenience and extends programming<br />

capabilities. A printout of all relevant system parameters is another<br />

valuable plus when using PC control. The Microsoft® Windows<br />

package will become available by the end of 1996.<br />

Service friendly design.<br />

Low instrument down time is accomplished by a high mean time between<br />

failure and quick instrument service. Special attention has been paid to<br />

these aspects of the concept, as is illustrated by the injection valve: AS<br />

<strong>3900</strong> will alert you in case the lifetime of the seal is exceeded or if the<br />

switching torque becomes too high. This allows preventive maintenance<br />

before injection performance degrades. And if necessary, the entire<br />

injection valve can be replaced in seconds with the unique Quick-fit valve<br />

mounting mechanism.