Cleaning or<br />

Replacing the<br />

Moistener Brush<br />

1. Lift the feed cover.<br />

2. Push down on the moistener<br />

brush button.<br />

3. Grasp the moistener brush assembly<br />

<strong>and</strong> pull it straight out<br />

towards you.<br />

4. Clean the moistening brush by<br />

running the brush under warm<br />

water.<br />

5. If you need to clean or replace<br />

the wick, go to Cleaning or<br />

Replacing the Wick procedure<br />

below. Otherwise go to step 6.<br />

6. Replace the existing clean<br />

moistener brush assembly,<br />

or install a new one by pushing<br />

the assembly back on its<br />

track until it snaps into position.<br />

7. Check to make sure that the<br />

flap blade of the moistener<br />

brush assembly is under<br />

(<strong>and</strong> not over) the stripper<br />

finger as shown here.<br />

<strong>DM400</strong>, DM500, DM550 Operating Guide<br />

Stripper Finger<br />

Flap<br />

Blade<br />

Moistener Brush<br />

Button<br />

Feed Deck<br />

Moistener Brush<br />

Assembly<br />

Moistener Brush<br />

Assembly<br />

8. Verify that the moistener brush assembly is perfectly level with the feed<br />

deck<br />