spanning-tree mstp edge-port<br />

spanning-tree mstp edge-port<br />

c e s Configures <strong>the</strong> interface as an Multiple Spanning Tree edge port and optionally a Bridge<br />

Protocol Data Unit (BPDU) guard.<br />

Syntax spanning-tree mstp edge-port [bpduguard]<br />

Parameters<br />

<strong>Command</strong> Modes INTERFACE<br />

<strong>Command</strong><br />

History<br />

Usage<br />

In<strong>for</strong>mation<br />

On an MSTP switch, a port configured as an edge port will immediately transition to <strong>the</strong><br />

<strong>for</strong>warding state. Only ports connected to end-hosts should be configured as an edge port.<br />

Consider an edge port similar to a port with spanning-tree portfast enabled.<br />

tc-flush-standard<br />

c e s Enable <strong>the</strong> MAC address flushing upon receiving every topology change notification.<br />

Syntax tc-flush-standard<br />

Defaults Disabled<br />

<strong>Command</strong> Modes CONFIGURATION<br />

<strong>Command</strong><br />

History<br />

mstp edge-port Enter <strong>the</strong> keywords mstp followed by <strong>the</strong> keyword edge-port to<br />

configure <strong>the</strong> interface as a Multiple Spanning Tree edge port.<br />

bpduguard (OPTIONAL) Enter <strong>the</strong> keyword bpduguard to prevent <strong>the</strong> port<br />

from participating in <strong>the</strong> active STP topology in case a BPDU shows<br />

up on a port unintentionally, is misconfigured, or subject to a DOS<br />

attack. This option places <strong>the</strong> port into an error disable state if a<br />

BPDU appears, and a message is logged <strong>for</strong> <strong>the</strong> administrator to take<br />

corrective action.<br />

Version 7.6.1.0 Added support <strong>for</strong> S-<strong>Series</strong><br />

Version 7.5.1.0 Added support <strong>for</strong> C-<strong>Series</strong><br />

Version 6.1.1.0 Support <strong>for</strong> BPDU guard added<br />

To disable, use <strong>the</strong> no tc-flush-standard command.<br />

Version 7.6.1.0 Added support <strong>for</strong> S-<strong>Series</strong><br />

Version 7.5.1.0 Added support <strong>for</strong> C-<strong>Series</strong><br />

Version 6.5.1.0 Introduced<br />

<strong>FTOS</strong> <strong>Command</strong> Line Interface <strong>Reference</strong>, version 7.6.1.0 487