line<br />

Parameters<br />

Defaults The IP address on <strong>the</strong> system that is closest to <strong>the</strong> Telnet address is used in <strong>the</strong> outgoing packets.<br />

<strong>Command</strong> Modes CONFIGURATION<br />

<strong>Command</strong><br />

History<br />

line c e s Enable and configure console and virtual terminal lines to <strong>the</strong> system.<br />

Syntax line {aux 0 | console 0 | vty number [end-number]}<br />

Parameters<br />

Defaults Not configured<br />

<strong>Command</strong> Modes CONFIGURATION<br />

<strong>Command</strong><br />

History<br />

interface Enter <strong>the</strong> following keywords and slot/port or number in<strong>for</strong>mation:<br />

• For an 100/1000 E<strong>the</strong>rnet interface, enter <strong>the</strong> keyword GigabitE<strong>the</strong>rnet<br />

followed by <strong>the</strong> slot/port in<strong>for</strong>mation.<br />

• For a 1-Gigabit E<strong>the</strong>rnet interface, enter <strong>the</strong> keyword GigabitE<strong>the</strong>rnet<br />

followed by <strong>the</strong> slot/port in<strong>for</strong>mation.<br />

• For Loopback interfaces, enter <strong>the</strong> keyword loopback followed by a number<br />

from zero (0) to 16383.<br />

• For a Port Channel, enter <strong>the</strong> keyword port-channel followed by a number:<br />

C-<strong>Series</strong> and S-<strong>Series</strong>: 1-128<br />

E-<strong>Series</strong>: 1 to 32 <strong>for</strong> E<strong>the</strong>rScale, 1 to 255 <strong>for</strong> TeraScale<br />

• For <strong>the</strong> SONET interfaces, enter <strong>the</strong> keyword sonet followed by slot/port<br />

in<strong>for</strong>mation.<br />

• For a 10-Gigabit E<strong>the</strong>rnet interface, enter <strong>the</strong> keyword<br />

TenGigabitE<strong>the</strong>rnet followed by <strong>the</strong> slot/port in<strong>for</strong>mation.<br />

• For a VLAN interface, enter <strong>the</strong> keyword vlan followed by a number from 1 to<br />

4094.<br />

Version 7.6.1.0 Support added <strong>for</strong> S-<strong>Series</strong><br />

Version 7.5.1.0 Introduced on C-<strong>Series</strong><br />

E-<strong>Series</strong> original <strong>Command</strong><br />

aux 0 Enter <strong>the</strong> keyword aux 0 to configure <strong>the</strong> auxiliary terminal connection.<br />

Note: This option is supported on E-<strong>Series</strong> only.<br />

console 0 Enter <strong>the</strong> keyword console 0 to configure <strong>the</strong> console port.<br />

vty number Enter <strong>the</strong> keyword vty followed by a number from 0 to 9 to configure a virtual<br />

terminal line <strong>for</strong> Telnet sessions.<br />

The system supports 10 Telnet sessions.<br />

end-number (OPTIONAL) Enter a number from 1 to 9 as <strong>the</strong> last virtual terminal line to<br />

configure. You can configure multiple lines at one time.<br />